Controller Rear Cable Connections and Ports
The following figure shows the locations of cable connectors and ports on the back of
the Oracle ZFS Storage ZS5-ES controller and the cables and devices that you would typically connect
to them.
Figure 3 Controller Rear Panel Cabling Reference
|
|
|
1
|
Power supply 0 input power
Power supply 1 input power
|
The controller has two power supply connectors, one for each power
supply.
Do not attach power cables to any installed power supplies until
you have finished connecting the data cables to the controller. The
controller goes into standby power mode and the Oracle ILOM service
processor initializes when the AC power cables are connected to the
power source. System messages might be lost after 60 seconds if the
controller is not connected to a terminal, PC, or
workstation.
Note -
Oracle ILOM will signal a fault on any installed power supply
that is not connected to an AC power source, since it might
indicate a loss of redundancy.
|
2
|
Serial management port (SER MGT)
|
The service processor SER MGT port uses an RJ-45 cable and is the
default connection to the Oracle ILOM service processor. This port
supports local connections to the controller and only recognizes
Oracle ILOM command-line interface (CLI) commands. Typically you
connect a terminal or a terminal emulator to this port.
Note -
This port does not support network connections.
|
3
|
Ethernet ports NET 3, NET 2, and NET 1
|
The 10-Gigabit Ethernet ports connect the appliance to the
network. See Ethernet Ports for
more information.
|
4
|
Ethernet port NET 0
|
Connect to the Oracle ILOM service processor using the Ethernet
in-band port NET 0 (remapped from the NET MGT port). The Oracle ILOM
sideband management feature enables you to use NET 0 to send and
receive Oracle ILOM commands to and from the SP.
Note -
The ZS5-ES NET MGT port is deactivated at the factory.
|
|
Related Information