On the primary controller, connect to the service processor (SP) and configure the primary network interface with the network parameters you gathered in Prerequisites.
For a serial port concentrator (for example, using telnet), connect and use root as the user name, and replace serial-concentrator portnumber with the appropriate value, for example: telnet serial-concentrator port number
For a network connection, connect using SSH and use root as the user name, and determine the IP address by accessing your DHCP server for the address assigned to the service processor MAC address (see the label on the controller), for example: ssh root@192.168.128.256.
To exit the shell interface before completing configuration, enter exit.
The final shell configuration screen appears, confirming that your system is ready for further configuration using the BUI.