Network Connection and IP Address Requirements
Prior to installation, network cables must be run from your existing network
infrastructure to the installation site. The network requirements for an
Oracle Exadata Storage Expansion Rack are as follows:
Table 72 Oracle Exadata Storage Expansion Rack Network IP Address Requirements
|
|
|
Full expansion rack
|
42
|
-
18 for administration (one per
Exadata Storage Server)
-
18 for Oracle ILOM (one per
Exadata Storage Server)
-
4 for switches (3 for InfiniBand and 1 for
Ethernet)
-
2 for monitoring electric current of the PDUs (PDU
connectivity is only required if the electric
current will be monitored remotely.)
|
Half expansion rack
|
24
|
-
9 for administration (one per
Exadata Storage Server)
-
9 for Oracle ILOM (one per
Exadata Storage Server)
-
4 for switches (3 for InfiniBand and 1 for
Ethernet)
-
2 for monitoring electric current of the PDUs (PDU
connectivity is only required if the electric
current will be monitored remotely.)
|
Quarter expansion rack
|
13
|
-
4 for administration (one per
Exadata Storage Server)
-
4 for Oracle ILOM (one per
Exadata Storage Server)
-
3 for switches (2 for InfiniBand and 1 for
Ethernet)
-
2 for monitoring electric current of the PDUs (PDU
connectivity is required only if the electric