SPARC SuperCluster T4-4 Owner's Guide

Exit Print View

Updated: February 2016
 
 

InfiniBand Private Network Physical Connections (SPARC T4-4 Servers)

Each SPARC T4-4 server contains four dual-ported Sun QDR InfiniBand PCIe Low Profile host channel adapters (HCAs). The InfiniBand HCAs are installed in the following express module ports in every SPARC T4-4 server:

  • Express module slot 1

  • Express module slot 7

  • Express module slot 9

  • Express module slot 12

See Card and Port Locations (SPARC T4-4 Servers) for more information on the location of the InfiniBand HCAs.

The two ports in each InfiniBand HCA (ports 1 and 2) connect to a different leaf switch to provide redundancy between the SPARC T4-4 servers and the leaf switches. The following figure shows how redundancy is achieved with the InfiniBand connections between the SPARC T4-4 servers and the leaf switches in a half rack configuration.

image:Graphic showing the InfiniBand connections between the SPARC                                 T4-4 servers and the leaf switches.

Note that only the physical connections for the InfiniBand private network are described in this section. Once the logical domains are created for each SPARC T4-4 server, the InfiniBand private network will be configured differently depending on the type of domain created for the SPARC T4-4 servers. The number of IP addresses needed for the InfiniBand network will also vary, depending on the type of domains created on each SPARC T4-4 server. For more information, see Understanding the SPARC SuperCluster T4-4 Configurations.