Oracle® Exadata Storage Server X5-2 Extreme Flash Service Manual

Exit Print View

Updated: January 2018
 
 

Install the Motherboard Assembly

  1. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.

    See Take Antistatic Measures.

  2. Carefully lift and place the motherboard assembly into the chassis [1].

    Tilt the motherboard to the right side to fit under the power supply assembly, level the motherboard and place it into the storage server chassis, then slide it to the rear of the storage server to engage the raised standoffs.


    image:Figure showing the motherboard assembly being installed in the storage                         server.
  3. Install the mid-wall into the chassis.
    1. Lift and place the mid-wall into the chassis [2].
    2. Using a No. 2 Phillips screwdriver, tighten the four green captive screws that secure the mid-wall to the bottom of the chassis [3].
      image:Figure showing the chassis mid-wall being secured in the storage                               server.
    3. Using a hex/flat head screwdriver, insert and tighten the screw on each side of the chassis to secure the mid-wall in the chassis [4].
  4. Reconnect the auxiliary signal cable to the motherboard from the front storage drive backplane [5].

    See Servicing the Storage Drive Backplane.


    image:Figure showing cables being connected to the motherboard                         assembly.
  5. Reconnect the power cables to the motherboard from the front storage drive backplane [5].

    See Servicing the Storage Drive Backplane.

  6. Reconnect the storage server intrusion switch cable to the motherboard [5].
  7. Reconnect the ribbon cables from left and right LED/USB indicator modules to the motherboard [6].

    See Servicing the Front LED/USB Indicator Modules.

  8. Reinstall the following components:

    Caution

    Caution  -  When reinstalling power supplies, it is important to reinstall them into the slots from which they were removed during the motherboard removal procedure; otherwise, the server key identity properties (KIP) data might be lost. When a server requires service, the KIP is used by Oracle to verify that the warranty on the server has not expired. For more information on KIP, see FRU Key Identity Properties (KIP) Automated Update.


  9. Install the air baffle.

    Install the air baffle by placing it into the storage server and lowering it to its installed position.

  10. Return the storage server to operation.
    1. Install the storage server top cover.

      See Install the Storage Server Top Cover.

    2. Return the storage server to the normal rack position.

      See Return the Storage Server to the Normal Rack Position.

    3. Reconnect the power cords to the power supplies, and power on the storage server.

      See Reconnect Power and Data Cables and Power On the Storage Server. Verify that the power supply AC OK LED is lit.


    Note -  IMPORTANT: When the motherboard is replaced, the key identity properties (KIP) of the motherboard is programmed by Oracle ILOM to contain the same KIP as the other quorum member components. If you have removed other quorum member components, you might need to manually program the product serial number (PSN) into the new motherboard. For more information, refer to FRU Key Identity Properties (KIP) Automated Update.