SPARC S7-2L Server Service Manual

Exit Print View

Updated: February 2019
 
 

Install the Twelve-Drive NVMe Backplane

  1. Lower the drive backplane into the server, position it in front of the eight stanoff hooks, then push the backplane down and into place.

    The standoff hooks fit into small openings in the drive backplane. Align the center double hook first, and ensure that all cables are out of the way.

  2. Using a No. 2 Phillips screwdriver, tighten the two green spring-mounted screws to secure the drive backplane to the chassis.
  3. Reconnect the cables to the drive backplane.
    1. Reconnect the auxiliary signal cable to the drive backplane.
    2. Reconnect the two power cables to the drive backplane.
    3. Connect the 12 NVMe cables to the drive backplane.

      Attach cables to the similarly-labeled connectors.

  4. Return the server to operation.
    1. Install the fan modules.

      See Install a Fan Module.

    2. Install the fan cover, and close the fan door.

      Replace the fan cover and secure it with two side screws.

    3. Fully install all storage drives you disengaged or removed.

      See Install a Drive or Drive Filler.

    4. Return the server to the normal operating position.

      See Return the Server to the Normal Operating Position.

    5. Reconnect the power cords to the power supplies, and power on the server.

      See Attach Power Cords and Power On the Server (Oracle ILOM) or Power On the Server (System Power Button). Verify that the power supply AC OK LED is lit.


    Note -  Authorized service personnel might need to reprogram the product serial number on the drive backplane. This number is used for service entitlement and warranty coverage. The correct product serial number is located on a label on the front of the chassis.
  5. Use the Oracle ILOM show faulty command to verify that the fault has been cleared.

    See Identify Faulted Components for more information on using the show faulty command.