Install a DIMM

  1. Remove a DIMM from the motherboard.

    See Remove a DIMM.

  2. Attach an antistatic wrist strap.

    Then unpack the DIMMs and place them on an antistatic mat.

  3. Install a DIMM into the motherboard by performing the following steps.
    image:This figure shows the DIMM socket release and alignment.
    No.
    Description
    1
    DIMM connector slot
    2
    DIMM connector key
    3
    DIMM ejector lever
    1. Ensure that the ejector levers at both ends of the DIMM slot are in a fully open position.
    2. Align each DIMM with the empty connector slot, aligning the notch in the DIMM with the key in the connector.

      The notch ensures that the DIMM is oriented correctly.

    3. Gently press the DIMM into the slot until the ejector tabs lock the DIMM in place.

    Repeat these steps until each DIMM has been installed.

  4. Return the server to operation.
    1. Install the top cover.

      See Replace the Top Cover.

    2. Return the server to the normal operating position.

      See Return the Server to the Normal Operating Position.

    3. Reinstall the power cords to the power supplies and power on the server.

      See Returning the Server to Operation.