虚拟化交换机通电并运行时,交换机中安装的模块应该正常工作。模块的状态可以与整个交换机的电源状态不同。使用此任务可显示虚拟化交换机中各个模块的电源信息。
-> show /SYS/MODULES/
/SYS/MODULES
Targets:
MODULE0
MODULE1
MODULE3
MODULE5
MODULE6
MODULE10
虚拟化交换机中 I/O 模块的编号为 0 到 11,模块 0 占用虚拟化交换机中的第一个(最左侧的)物理插槽。
-> show /SYS/MODULES/MODULEX power_state
其中 X 是介于 0 到 11 之间的编号,该编号与您想要显示其信息的模块插槽相对应。
例如,要显示模块 3 的电源状态,可键入:
-> show /SYS/MODULES/MODULE3 power_state
/SYS/MODULES/MODULE3
Properties:
power_state = On
-> show /SYS/MODULES/MODULE3/0V85_OK/
/SYS/MODULES/MODULE3/0V85_OK
Targets:
Properties:
type = Voltage
ipmi_name = MODULE3/0V85_OK
class = Discrete Sensor
value = State Asserted
alarm_status = cleared
-> show /SYS/MODULES/MODULE3/1V0_OK/
/SYS/MODULES/MODULE3/1V0_OK
Targets:
Properties:
type = Voltage
ipmi_name = MODULE3/1V0_OK
class = Discrete Sensor
value = State Asserted
alarm_status = cleared
-> show /SYS/MODULES/MODULE3/1V2_OK
/SYS/MODULES/MODULE3/1V2_OK
Targets:
Properties:
type = Voltage
ipmi_name = MODULE3/1V2_OK
class = Discrete Sensor
value = State Asserted
alarm_status = cleared
-> show /SYS/MODULES/MODULE3/1V8_OK/
/SYS/MODULES/MODULE3/1V8_OK
Targets:
Properties:
type = Voltage
ipmi_name = MODULE3/1V8_OK
class = Discrete Sensor
value = State Asserted
alarm_status = cleared
-> show /SYS/MODULES/MODULE3/2V5_OK/
/SYS/MODULES/MODULE3/2V5_OK
Targets:
Properties:
type = Voltage
ipmi_name = MODULE3/2V5_OK
class = Discrete Sensor
value = State Asserted
alarm_status = cleared
-> show /SYS/MODULES/MODULE3/3V3_OK/
/SYS/MODULES/MODULE3/3V3_OK
Targets:
Properties:
type = Voltage
ipmi_name = MODULE3/3V3_OK
class = Discrete Sensor
value = State Asserted
alarm_status = cleared