Go to main content
Oracle EDR InfiniBand 交换机和虚拟化 I/O 系统管理指南

退出打印视图

更新时间: 2016 年 11 月
 
 

/SYS 电源机箱目标和属性

对 /SYS/PSx 目标使用 show 命令可显示有关电源的信息和状态。使用 set 命令可配置 clear_fault_action 属性以手动清除电源故障。


注 -  未列出标为 Not Supported 或 N/A 的属性。
Oracle ILOM 目标
属性
说明
/SYS/PSx
  • type = Power Supply

  • ipmi_name = PSx

  • fru_manufacturer = Delta Electronics

  • fru_part_number = 7065505-01

  • fru_serial_number = C94928

  • fault_state = OK

  • clear_fault_action = (none)

电源 x 信息。
/SYS/PSx/INPUT_POWER
  • type = Power Unit

  • ipmi_name = PSx/IN_POWER

  • class = Threshold Sensor

  • value = 209.916 Watts

  • alarm_status = cleared

电源 x 输入功率信息。
/SYS/PSx/I_IN
  • type = Current

  • ipmi_name = PSx/I_IN

  • class = Threshold Sensor

  • value = 1.827 Amps

  • alarm_status = cleared

电源 x 输入电流信息。
/SYS/PSx/I_OUT
  • type = Current

  • ipmi_name = PSx/I_OUT

  • class = Threshold Sensor

  • value = 16.00 Amps

  • alarm_status = cleared

电源 x 输出电流信息。
/SYS/PSx/OUTPUT_POWER
  • type = Power Unit

  • ipmi_name = PSx/OUT_POWER

  • class = Threshold Sensor

  • value = 180.000 Watts

  • alarm_status = cleared

电源 x 输出功率信息。
/SYS/PSx/PRSNT
  • type = Entity Presence

  • ipmi_name = PSx/PRSNT

  • class = Discrete Sensor

  • value = Present

  • alarm status = cleared

电源 x 的存在和报警状态。
/SYS/PSx/PWROK
  • type = Power Supply

  • ipmi_name = PSx/PRSNT

  • class = Discrete Sensor

  • value = State Asserted

  • alarm status = cleared

电源 x 功率状态。
/SYS/PSx/V_IN
  • type = Voltage

  • ipmi_name = PSx/V_IN

  • class = Threshold Sensor

  • value = 119.000 Volts

  • upper_nonrecov_threshold = 255.000 Volts

  • upper_critical_threshold = 252.000 Volts

  • lower_critical_threshold = 100.000 Volts

  • lower_nonrecov_threshold = 90.000 Volts

  • alarm_status = cleared

电源 x 输入电压信息。
/SYS/PSx/V_OUT
  • type = Voltage

  • ipmi_name = PSx/V_OUT

  • class = Threshold Sensor

  • value = 12.000 Volts

  • upper_nonrecov_threshold = 20.000 Volts

  • upper_critical_threshold = 14.000 Volts

  • lower_critical_threshold = 10.000 Volts

  • alarm_status = cleared

电源 x 输出电压信息。
/SYS/PS_3V3
  • type = Voltage

  • class = Threshold Sensor

  • value = 3.412 Volts

  • upper_nonrecov_threshold = 3.783 Volts

  • upper_critical_threshold = 3.685 Volts

  • upper_noncritical_threshold = 3.471 Volts

  • lower_noncritical_threshold = 3.120 Volts

  • lower_critical_threshold = 2.944 Volts

  • lower_nonrecov_threshold = 2.789 伏

  • alarm_status = cleared

3.3 伏功率信息。

相关信息