/SYS 电源机箱目标和属性
对 /SYS/PSx 目标使用 show 命令可显示有关电源的信息和状态。使用 set 命令可配置 clear_fault_action 属性以手动清除电源故障。
注 -
未列出标为 Not Supported 或 N/A 的属性。
|
|
|
/SYS/PSx
|
-
type = Power Supply
-
ipmi_name = PSx
-
fru_manufacturer = Delta Electronics
-
fru_part_number = 7065505-01
-
fru_serial_number = C94928
-
fault_state = OK
-
clear_fault_action = (none)
|
电源 x 信息。
|
/SYS/PSx/INPUT_POWER
|
-
type = Power Unit
-
ipmi_name = PSx/IN_POWER
-
class = Threshold Sensor
-
value = 209.916 Watts
-
alarm_status = cleared
|
电源 x 输入功率信息。
|
/SYS/PSx/I_IN
|
-
type = Current
-
ipmi_name = PSx/I_IN
-
class = Threshold Sensor
-
value = 1.827 Amps
-
alarm_status = cleared
|
电源 x 输入电流信息。
|
/SYS/PSx/I_OUT
|
-
type = Current
-
ipmi_name = PSx/I_OUT
-
class = Threshold Sensor
-
value = 16.00 Amps
-
alarm_status = cleared
|
电源 x 输出电流信息。
|
/SYS/PSx/OUTPUT_POWER
|
|
电源 x 输出功率信息。
|
/SYS/PSx/PRSNT
|
-
type = Entity Presence
-
ipmi_name = PSx/PRSNT
-
class = Discrete Sensor
-
value = Present
-
alarm status = cleared
|
电源 x 的存在和报警状态。
|
/SYS/PSx/PWROK
|
-
type = Power Supply
-
ipmi_name = PSx/PRSNT
-
class = Discrete Sensor
-
value = State Asserted
-
alarm status = cleared
|
电源 x 功率状态。
|
/SYS/PSx/V_IN
|
-
type = Voltage
-
ipmi_name = PSx/V_IN
-
class = Threshold Sensor
-
value = 119.000 Volts
-
upper_nonrecov_threshold = 255.000 Volts
-
upper_critical_threshold = 252.000 Volts
-
lower_critical_threshold = 100.000 Volts
-
lower_nonrecov_threshold = 90.000 Volts
-
alarm_status = cleared
|
电源 x 输入电压信息。
|
/SYS/PSx/V_OUT
|
-
type = Voltage
-
ipmi_name = PSx/V_OUT
-
class = Threshold Sensor
-
value = 12.000 Volts
-
upper_nonrecov_threshold = 20.000 Volts
-
upper_critical_threshold = 14.000 Volts
-
lower_critical_threshold = 10.000 Volts
-
alarm_status = cleared
|
电源 x 输出电压信息。
|
/SYS/PS_3V3
|
-
type = Voltage
-
class = Threshold Sensor
-
value = 3.412 Volts
-
upper_nonrecov_threshold = 3.783 Volts
-
upper_critical_threshold = 3.685 Volts
-
upper_noncritical_threshold = 3.471 Volts
-
lower_noncritical_threshold = 3.120 Volts
-
lower_critical_threshold = 2.944 Volts
-
lower_nonrecov_threshold = 2.789 伏
-
alarm_status = cleared
|
3.3 伏功率信息。
|
|