Field Activity Step Upload Staging

You must create a field activity step upload staging record for each step that was completed. The name of this table is CI_​FA_​STP_​STG_​UP. The following table describes each column on this file.

Column Name

Length

Req'd

Data Type

Comments

FA_​ID

10

Y

A/N

This is the ID of the field activity whose completion details are being supplied.

STEP_​SEQ_​NBR

3

Y

N

This is the sequence number of the field activity step whose completion details are being supplied.

FA_​STP_​UP_​STAT_​FLG

2

Y

A/N

This is the status of the upload record. This must be set to P for Pending.

FA_​STEP_​TY_​ACT_​FLG

2

Y

A/N

This is the type of step whose completion details are being supplied. This must be one of the following values:

NS - Connect Service Point, DS - Disconnect Service Point, IM - Install Meter, NM - Turn On Meter, FM - Turn Off Meter, MR - Read Meter, RM - Remove Meter, II - Install Item, NI - Turn On Item, FI - Turn Off Item, RI - Remove Item

BADGE_​NBR

30

See note

A/N

Badge Number is the badge number of the meter or item involved with the field activity step. It is required for the following step types: Install Meter, Turn On Meter, Turn Off Meter, Read Meter, Remove Meter, Install Item, Turn On Item, Turn Off Item, Remove Item

READ_​DT

10

See note

Date

This must correspond with a read date on one of the meter read upload staging records. It is required for the following step types: Install Meter, Turn On Meter, Turn Off Meter, Read Meter, Remove Meter

READ_​TIME

15

See note

Time

This must correspond with a read time on one of the meter read upload staging records. It is required for the following step types: Install Meter, Turn On Meter, Turn Off Meter, Read Meter, Remove Meter

DISCON_​LOC_​CD

4

See note

A/N

This is the disconnect location code that identifies where a service point has been disconnected. It is required for the Disconnect Service Point step type.

ON_​OFF_​FLG

2

See note

A/N

Set this to 0 if the meter / item was turned off.

Set this to 1 if the meter / item was turned on.

It is required for the following step types: Install Meter, Install Item.

EVENT_​DTTM

26

See note

Date / Time

This the date and time an item was installed, removed, turned on or off. It is required for the following step types: Install Item, Turn On Item, Turn Off Item, Remove Item

STK_​LOC_​CD

12

See note

A/N

This is the stock location where the meter / item is stored upon removal from a service point. This is required for the following step types if the meter's meter type or the item's item type tracks location: Remove Item, Remove Meter. Refer to The Big Picture Of Asset Inventory for more information.