Installation

About Blade Features and Components

Blade Features

Blade Front Panel Features

Blade Rear Panel Features

UEFI BIOS

Specifications

Installing the Blade

Installation Overview

Preparing to Install the Blade

Shipping Inventory List

ESD and Safety Precautions

Additional Components

Prepare the Chassis

Install Your Blade

Cabling the Blade

Attach the 3-Cable Dongle to the Blade

Attach a VGA Monitor to the Dongle Video Connector

Attach a Keyboard and Mouse to the Dongle or Blade

Attach a Serial Device to the Dongle

Cable the CMM NET MGT Port

Connecting to Oracle ILOM

Oracle ILOM Overview

Determining the Oracle ILOM SP IP Address

Logging In to Blade SP Oracle ILOM

Accessing the Blade Console Through Oracle ILOM

Setting Up Software and Firmware

Accessing Oracle System Assistant

Set Up Software and Firmware (Oracle System Assistant)

Setting Up an Operating System and Drivers

Preparing the Storage Drives to Install an Operating System

Supported Host Bus Adapters

Prepare the Storage Drives (Oracle System Assistant)

Make a Virtual Drive Bootable (LSI WebBIOS Utility)

Configuring the Preinstalled Oracle Solaris OS

Oracle Solaris OS Documentation

Configuration Worksheet

Configure Preinstalled Oracle Solaris 11

Configuring Preinstalled Oracle VM Software

Oracle VM Server Configuration Worksheet

Configure the Preinstalled Oracle VM Server

Updating Oracle VM Software

Getting Started With Oracle VM

Troubleshoot Installation Issues

Powering Off the Blade for Graceful Shutdown

Powering Off the Blade for Immediate Shutdown

Resetting the Blade

Identifying Blade Faults

Troubleshooting Blade Power States

Technical Support Information Worksheet

Locating the System Serial Number

Oracle Solaris OS Installation and Setup

About Oracle Solaris OS Installation

Oracle Solaris Installation Task Table

Supported OS Versions and Latest Information

OS Installation Options

Preparing to Install the OS

Obtaining Oracle Solaris Documentation

Setting Up the Installation Session

Setting Up the BIOS

Installing the Oracle Solaris OS

Install Supported Versions of the Oracle Solaris OS

Identify Logical and Physical Network Interface Names

Installing Server System Tools and Accessing Drivers

Oracle VM OS Installation and Setup

About Oracle VM Software Installation

Oracle VM Installation Task Table

Oracle VM Overview

Oracle VM Installation Options

Oracle System Assistant

Preparing for Oracle VM Server Installation

Preparing the Installation Environment

Creating a Virtual Disk and Setting the Boot Disk

Verify BIOS Optimal Defaults

Installing Oracle VM Server

Install Oracle VM Server (Oracle System Assistant)

Installing Oracle VM Server (Manually)

Completing the Oracle VM Installation

Install Server System Tools

Update the Oracle VM Drivers

Creating and Managing Oracle VM Resources

Linux OS Installation and Setup

About Linux Installation

Supported OS Versions and Latest Information

OS Installation Options

Oracle System Assistant

Preparing to Install the OS

Downloading Installation Media Kits

Setting Up the Installation Method

Setting Up the BIOS

Installing the Operating System

Identifying Logical and Physical Network Interface Names for Linux OS Configuration

Install a Linux OS (Oracle System Assistant)

Installing a Linux OS (Manually)

Installing Server System Tools and Updating Drivers

Updating a Linux OS to a New Version

Windows OS Installation and Setup

About Windows OS Installation

Supported OS Versions and Latest Information

OS Installation Options

Oracle System Assistant

Preparing to Install the OS

Setting Up the Installation Method

Setting Up the BIOS

Installing the Windows OS

Install Windows (Oracle System Assistant)

Install Windows Server 2008 R2 Manually

Install Windows Server 2008 (PXE)

Installing Server System Tools and Updating Drivers

VMware ESXi Installation and Setup

About VMware ESXi 5 Installation

Installation Task Map

VMware ESXi 5 and Blade Documentation

Software Installation Options

Single-Server Interactive Installation Methods

Preparing for ESXi 5 Installation

Set Up for Local Installation

Set Up for Remote Installation

Gather Required Information

Enable UEFI BIOS

Verify BIOS Optimal Defaults

Creating a Virtual Disk and Setting the Boot Disk

Installing VMware ESXi 5

Install VMware ESXi 5 Using Local or Remote Interactive Installation

Update VMware ESXi 5

Install VMware ESXi 5 Drivers

Administration

Planning the System Management Environment

Choosing Tools for Single System Management

Choosing Tools for Multiple System Management

System Management Tools Overview

Common System Management Tasks

Common System Administrative Tasks

Evaluating the Server Environment

Accessing System Management Tools

Accessing Oracle System Assistant

Accessing Oracle ILOM

Accessing Oracle Hardware Management Pack

Setting Up the Blade With Oracle System Assistant

Overview of Oracle System Assistant

Using the Help and Exit Buttons

Using Oracle System Assistant for Server Configuration

Oracle System Assistant Administrative Tasks

Managing a Server Using Oracle System Assistant

Configure the Server Using Oracle System Assistant

View System Overview

View System Inventory

Configure Network Settings

Get Updates for a New Platform Software Release

Update Firmware

Configure Hardware for RAID

Configure Hardware for Oracle ILOM SP

Install an Operating System

Set Preferences to Disable Oracle System Assistant

Set Preferences for Keyboard Language

Perform Advanced Tasks to Access Oracle System Assistant Shell

Perform Advanced Tasks to Check Media Integrity

Maintaining Oracle System Assistant

Troubleshooting Oracle System Assistant

Mounting the Oracle System Assistant USB Flash Drive

Setting Up Software and Firmware

Set Up Software and Firmware (OSA)

Set Up Software and Firmware (Oracle ILOM)

Set Up Software and Firmware (Oracle Hardware Management Pack)

Managing Server Policies Using Oracle ILOM

Oracle ILOM Features

Oracle ILOM Features for x86 Sun Servers

Sideband Management

Service Processor Power-On Policies

Power Management Policies Supported

Diagnostics Using Pc-Check and NMI

Control Next Boot Device

FRU TLI Auto-Update

Switch Serial Port Output to Host Management Console

Back Up and Restore BIOS Configuration

Administer Open Problems

Clear Blade Faults

Configure Management Policies Using Oracle ILOM (Web)

Configure Management Policies Using Oracle ILOM (CLI)

Configuring RAID

Supported HBA REMs

RAID Considerations

Creating a RAID Volume

Setting Up the Blade With BIOS Setup Utility

Access BIOS Setup Utility Menus

Navigate BIOS Setup Utility Menus

BIOS Key Mappings

BIOS Setup Utility Menu Overview

Selecting Legacy and UEFI BIOS

Configuring the UEFI BIOS Boot Mode

Supported Boot Modes

UEFI BIOS Advantages

Configuration Utilities for Add-In Cards

Select UEFI or Legacy BIOS Boot Mode

Common BIOS Setup Utility Tasks

Verify BIOS Factory Default Settings

Select the Boot Device

Configure TPM Support

Configure SP Network Settings

Legacy BIOS Option ROM Allocation Considerations

Configure Option ROM Settings

Modify Device Configuration

Allocating I/O Resources

Configure iSCSI Virtual Drives

Exit BIOS Setup Utility

BIOS Setup Utility Screen Reference

BIOS Main Menu Selections

BIOS Advanced Menu Selections

BIOS IO Menu Selections

BIOS Boot Menu Selections

BIOS UEFI Driver Control Menu Selections

BIOS Save & Exit Menu Selections

BIOS LSI MegaRAID Configuration Utility Screen Reference

Accessing BIOS LSI MegaRAID Configuration Utility Controller Management Menus

BIOS LSI MegaRAID Configuration Utility Controller Management Selections

BIOS LSI MegaRAID Configuration Utility Drive Management Menu Selections

BIOS LSI MegaRAID Configuration Utility Virtual Drive Management Menu Selections

BIOS LSI MegaRAID Configuration Utility Enclosure Management Menu Selections

Identifying Hardware Components and SNMP Messages

Identifying System Hardware Components

Table Legend

System Board Components (Sensors)

Sensors

Field Replaceable Units (FRUs)

SNMP and PET Traps

Service

About the Netra Blade X3-2B

Product Description

Front Panel Features

Front Panel LEDs

Rear Panel Features

Supported Chassis

About Oracle ILOM

About the Chassis Monitoring Module (CMM)

Replaceable Blade Components

Preparing the Blade for Service

Obtaining the Serial Number

Powering Off the Blade

Performing ESD and Antistatic Prevention Measures

Using the Locate LED to Identify the Blade

Removing the Blade from the Chassis

Removing the Blade Top Cover

Removing or Inserting Blade Filler Panels

Removing or Inserting Component Filler Panels

Connecting the Multi-port Cable

Servicing Blade Components

Servicing a Storage Drive

Servicing DIMMs

Servicing the System Battery

Servicing USB Flash Drives

Servicing a Fabric Expansion Module

Servicing a RAID Expansion Module

Servicing a Processor and Heat Sink Assembly

Servicing the Blade and Motherboard Assembly

Returning Blade to Operation

Install the Blade Top Cover

Install the Blade in the Chassis

Powering On the Blade

Power On from Oracle ILOM SP (CLI)

Power On From Oracle ILOM SP (Web)

Troubleshooting the Blade

Diagnosing Hardware Faults

Using LED Indicators

Using the DIMM and Processor Test Circuit

Using Diagnostic Tools

Troubleshooting Power States

Firmware and Software Troubleshooting

BIOS POST Checkpoints

About POST Code Checkpoint Memory Testing

Viewing POST Code Checkpoints

Configure Boot Settings

POST Code Checkpoint Reference

Index

SNMP and PET Traps

This section describes Simple Network Management Protocol (SNMP) and Platform Event Trap (PET) messages that are generated by devices being monitored by Oracle ILOM.

SNMP traps are generated by SNMP agents that are enabled on the SNMP devices being managed by Oracle ILOM. Oracle ILOM receives the SNMP traps and converts them into SNMP event messages that appear in the event log.

Table 6 Memory SNMP Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
sunHwTrapMemoryFault
fault.memory.channel.misconfig ured
Major -- A memory component is suspected of causing a fault.
/MB/P/D
sunHwTrapMemoryFault Cleared
fault.memory.channel.misconfig ured
Informational -- A memory component fault has been cleared.
/MB/P/D
sunHwTrapComponentFault
fault.memory.intel.dimm.none
Major -- A memory component is suspected of causing a fault.
/MB
fault.memory.conroller.inputinvalid
fault.memory.controller.initfailed
fault.memory.intel.dimm.popul ation-invalid
sunHwTrapComponentFault Cleared
fault.memory.intel.dimm.none
Informational -- A memory component fault has been cleared.
/MB
fault.memory.conroller.inputinvalid
fault.memory.controller.initfailed
fault.memory.intel.dimm.popul ation-invalid
sunHwTrapMemoryFault
fault.memory.intel.dimm.incom patible
Major -- A memory component is suspected of causing a fault.
/MB/P/D
fault.memory.intel.dimm.incom patible-maxranks
fault.memory.intel.dimm.incom patible-quadrank
sunHwTrapMemoryFault Cleared
fault.memory.intel.dimm.incom patible
Informational -- A memory component fault has been cleared.
/MB/P/D
fault.memory.intel.dimm.incom patible-maxranks
fault.memory.intel.dimm.incom patible-quadrank

Table 7 Environmental SNMP Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
sunHwTrapPower SupplyFault
fault.chassis.env.power.loss
Major -- A power supply component is suspected of causing a fault
/PS
sunHwTrapPower SupplyFault Cleared
Cleared fault.chassis.env.power.loss
Informational -- A power supply component fault has been cleared
/PS
sunHwTrap ComponentFault
fault.chassis.env.temp.over-fail
Major -- A component is suspected of causing a fault
/SYS/
sunHwTrap ComponentFault Cleared
fault.chassis.env.temp.over-fail
Informational -- A component fault has been cleared
/SYS/
sunHwTrapTempCrit Threshold Exceeded
Lower critical threshold exceeded
Major -- A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting
/DBP/T_A MB
sunHwTrapTempCrit Threshold Deasserted
Lower critical threshold no longer exceeded
Informational -- A temperature sensor has reported that its value is in the normal operating range
/DBP/T_A MB
sunHwTrapTempNonCrit ThresholdExceeded
Upper noncritical threshold exceeded
Minor -- A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting
/DBP/T_A MB
sunHwTrapTempOk
Upper noncritical threshold no longer exceeded
Informational -- A temperature sensor has reported that its value is in the normal operating range
/DBP/T_A MB
sunHwTrapTempFatal ThresholdExceeded
Lower fatal threshold exceeded
Critical -- A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting
/DBP/T_A MB
sunHwTrapTempFatal ThresholdDeasserted
Lower fatal threshold no longer exceeded
Informational -- A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting
/DBP/T_A MB
sunHwTrapTempFatal ThresholdExceeded
Upper fatal threshold exceeded
Critical -- A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting
/T_AMB
sunHwTrapTempCrit Threshold Exceeded
Upper critical threshold exceeded
Major -- A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting
/T_AMB
sunHwTrapTempCrit Threshold Deasserted
Upper critical threshold no longer exceeded
Informational -- A temperature sensor has reported that its value is in the normal operating range
/T_AMB
sunHwTrapTempFatal ThresholdDeasserted
Upper fatal threshold no longer exceeded
Informational -- A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting
/T_AMB
sunHwTrap ComponentError
Assert
Major -- A power supply sensor has detected an error
/HOT

/PSn/Sn/V_ OUT_OK

/PSn/Sn/V_ OUT_OK

/PSn/Sn/V_ OUT_OK

/PSn/Sn/V_ OUT_OK

/PSn/Sn/V_ OUT_OK

/PSn/Sn/V_ OUT_OK

sunHwTrap ComponentOk
Deassert
Informational -- A power supply sensor has returned to its normal state

Table 8 Device SNMP Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
sunHwTrapComponentFault
fault.chassis.device.missing
Major; A component is suspected of causing a fault
/SYS/
sunHwTrapComponentFault Cleared
fault.chassis.device.missing
Informational; A component fault has been cleared
/SYS/
sunHwTrapComponentFault
fault.chassis.device.fail
Major; A component is suspected of causing a fault
/CMM
sunHwTrapComponentFault Cleared
fault.chassis.device.fail
Informational; A component fault has been cleared
/CMM
sunHwTrapIOFault
fault.chassis.device.fail
Major; A component in the IO subsystem is suspected of causing a fault
/NEM
sunHwTrapIOFaultCleared
fault.chassis.device.fail
Informational; An IO subsystem component fault has been cleared
/NEM

Table 9 Power Supply SNMP Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
sunHwTrapPowerSupplyError
Assert
Major; A power supply sensor has detected an error
/PWRBS
sunHwTrapPowerSupplyOk

Deassert

Informational; A power supply sensor has returned to its normal state

/PWRBS

sunHwTrapPowerSupplyFault
fault.chassis.env.power.loss
Major; A power supply component is suspected of causing a fault
/PS
sunHwTrapPowerSupplyFault Cleared
fault.chassis.env.power.loss
Informational; A power supply component fault has been cleared
/PS

Platform Event Trap (PET) events are generated by systems with Alert Standard Format (ASF) or an IPMI baseboard management controller. The PET events provide advance warning of possible system failures.

Table 10 System Power Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
petTrapPowerUnitState DeassertedAssert
PowerSupply sensor ASSERT
Critical; A run-time power fault has occurred
/PWRBS
petTrapPowerSupplyStat eAssertedAssert
PowerSupply sensor DEASSERT
Informational; Power supply is connected to AC Power
/PWRBS

Table 11 Entity Present Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
petTrapProcessorPresence DetectedDeassert
EntityPresence Insert
Critical; A processor is absent or has been removed.
/HOSTPOWER

/CMM/PRSNT

/MB/REM/PRSNT

/MB/FEM0/PRSNT

/MB/FEM1/PRSNT

/PEM0/PRSNT

/PEM1/PRSNT

/MB/P0/PRSNT

/MB/P1/PRSNT

/MB/P0/D0/PRSNT

/MB/P0/D1/PRSNT

/MB/P0/D2/PRSNT

/MB/P0/D3/PRSNT

/MB/P0/D4/PRSNT

/MB/P0/D5/PRSNT

/MB/P0/D6/PRSNT

/MB/P0/D7/PRSNT

/MB/P0/D8/PRSNT

/MB/P1/D0/PRSNT

/MB/P1/D1/PRSNT

/MB/P1/D2/PRSNT

/MB/P1/D3/PRSNT

/MB/P1/D4/PRSNT

/MB/P1/D5/PRSNT

/MB/P1/D6/PRSNT

/MB/P1/D7/PRSNT

/MB/P1/D8/PRSNT

/HDD0/PRSNT

/HDD1/PRSNT

/HDD2/PRSNT

/HDD3/PRSNT/NEM0/PRSNT /NEM1/PRSNT

/BL0/PRSNT /BL1/PRSNT

/BL2/PRSNT /BL3/PRSNT

/PS0/PRSNT /PS1/PRSNT

/PS2/PRSNT /PS3/PRSNT

petTrapEntityPresenceDe viceInsertedAssert
EntityPresence Remove
Informational; A device is present or has been inserted
/HOSTPOWER

/CMM/PRSNT

/MB/REM/PRSNT

/MB/FEM0/PRSNT

/MB/FEM1/PRSNT

/PEM0/PRSNT

/PEM1/PRSNT

/MB/P0/PRSNT

/MB/P1/PRSNT

/MB/P0/D0/PRSNT

/MB/P0/D1/PRSNT

/MB/P0/D2/PRSNT

/MB/P0/D3/PRSNT

/MB/P0/D4/PRSNT

/MB/P0/D5/PRSNT

/MB/P0/D6/PRSNT

/MB/P0/D7/PRSNT

/MB/P0/D8/PRSNT

/MB/P1/D0/PRSNT

/MB/P1/D1/PRSNT

/MB/P1/D2/PRSNT

/MB/P1/D3/PRSNT

/MB/P1/D4/PRSNT

/MB/P1/D5/PRSNT

/BL0/PRSNT

/MB/P1/D6/PRSNT

/MB/P1/D7/PRSNT

/MB/P1/D8/PRSNT

/HDD0/PRSNT

/HDD1/PRSNT

/HDD2/PRSNT

/HDD3/PRSNT

/NEM0/PRSNT

/NEM1/PRSNT /BL1/PRSNT

/BL2/PRSNT /BL3/PRSNT

/PS0/PRSNT /PS1/PRSNT

/PS2/PRSNT /PS3/PRSNT

Table 12 Environmental Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
petTrapTemperatureState DeassertedDeassert
Temperature sensor ASSERT
Informational; Temperature event occurred
/HOT
petTrapTemperatureState DeassertedDeassert
Temperature sensor DEASSERT
Critical; Temperature event occurred
/HOT
petTrapTemperatureUppe rNonRecoverableGoingL owDeassert
Temperature Upper non-critical threshold has been exceeded
Major; Temperature has decreased below upper non-recoverable threshold
/MB/T_AMB
petTrapTemperatureState AssertedAssert
Temperature Upper non-critical threshold no longer exceeded
Critical; Temperature event occurred. Possible cause: CPU is too hot.
/MB/T_AMB
petTrapTemperatureUppe rCriticalGoingHigh
Temperature Lower fatal threshold has been exceeded
Major; Temperature has increased above upper critical threshold
/MB/T_AMB
petTrapTemperatureUppe rCriticalGoingLowDeasse rt
Temperature Lower fatal threshold no longer exceeded
Warning; Temperature has decreased below upper critical threshold
/MB/T_AMB
petTrapTemperatureLowe rNonCriticalGoingLow
petTrapTemperatureLowe rNonCriticalGoingLow
Warning; Temperature has decreased below lower non-critical threshold
/MB/T_AMB
Warning; Temperature has decreased below lower non-critical threshold
Temperature Lower critical threshold no longer exceeded
Informational; Temperature has returned to normal
/MB/T_AMB
petTrapTemperatureUppe rNonCriticalGoingHigh
Temperature Upper critical threshold has been exceeded
Warning; Temperature has increased above upper non-critical threshold
/MB/T_AMB
petTrapTemperatureUppe rNonCriticalGoingLowDe assert
Temperature Upper critical threshold no longer exceeded
Informational; Temperature has returned to normal
/MB/T_AMB
petTrapTemperatureLowe rCriticalGoingLow
Temperature Lower fatal threshold has been exceeded
Major; Temperature has decreased below lower critical threshold
/MB/T_AMB
petTrapTemperatureLowe rCriticalGoingHighDeassert
Temperature Lower fatal threshold no longer exceeded
Warning; Temperature has increased above lower critical threshold
/MB/T_AMB
petTrapTemperatureLowe rNonRecoverableGoingH ighDeassert
Temperature Lower non-critical threshold has been exceeded
Major; Temperature has increased above lower non-recoverable threshold
/MB/T_AMB
petTrapTemperatureUppe rNonRecoverableGoingH igh
Temperature Lower non-critical threshold no longer exceeded
Critical; Temperature has increased above upper non-recoverable threshold

Table 13 Component, Device, and Firmware Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
petTrapOEMStateDeasser tedAssert
petTrapOEMStateDeasser tedAssert
Informational; A fault has occurred (OEM State Deasserted assert)
/MB/FEMn/FAULT
petTrapOEMPredictiveFai lureAsserted
OEMReserved sensor DEASSERT
Major; OEM Predictive Failure Asserted
/MB/FEMn/FAULT
petTrapOEMPredictiveFai lureDeasserted
OEMReserved reporting Predictive Failure
Informational; OEM Predictive Failure Deasserted
/CMM/ERR /NEMn/ERR /NEMn/ERR /BLn/ERR /BLn/ERR /BLn/ERR /BLn/ERR
petTrapSystemFirmwareE rror
OEMReserved Return to normal
Informational; System Firmware Error reported
petTrapModuleBoardTran sitionToRunningAssert
Module Transition to Running assert
Informational
/NEMn/STATE /NEMn/STATE /BLn/STATE /BLn/STATE /BLn/STATE /BLn/STATE
petTrapModuleBoardTran sitionToInTestAssert
Module Transition to In Test assert
Informational
petTrapModuleBoardTran sitionToPowerOffAssert
Module Transition to Power Off assert
Informational
petTrapModuleBoardTran sitionToOnLineAssert
Module Transition to On Line assert
Informational
Undocumented PET 1378820
Module Transition to Off Line assert
Informational
petTrapModuleBoardTran sitionToOffDutyAssert
Module Transition to Off Duty assert
Informational
/NEMn/STATE /NEMn/STATE /BLn/STATE /BLn/STATE /BLn/STATE /BLn/STATE
petTrapModuleBoardTran sitionToDegradedAssert
Module Transition to Degraded assert
Informational
petTrapModuleBoardTran sitionToPowerSaveAssert
Module Transition to Power Save assert
Informational
petTrapModuleBoardInst allErrorAssert
Module Install Error assert
Informational
Undocumented PET 132097
Voltage reporting Predictive Failure
Informational
/PSn/V_IN_ERR /PSn/V_IN_ERR /PSn/V_IN_ERR /PSn/V_IN_ERR
Undocumented PET 132096
Voltage Return to normal
Informational

Table 14 Power Supply Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
petTrapVoltageStateDeass ertedDeassert
Voltage sensor ASSERT
Informational; Voltage event occurred
/PSn/V_OUT_OK /PSn/V_OUT_OK /PSn/V_OUT_OK /PSn/V_OUT_OK
petTrapVoltageStateAsser tedDeassert
Voltage sensor DEASSERT

Table 15 Fan Events

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
petTrapFanPredictiveFail ureDeasserted
Fan reporting Predictive Failure
Informational; Fan Predictive Failure state has been cleared
/FMn/ERR
petTrapFanLowerNonRecoverableGoingLow
Fan Return to normal
Critical; Fan speed has decreased below lower non-recoverable threshold. Fan failed or removed.
Related Information