Default Level and Verbosity
(default_level=)
(default_verbosity=)
|
Level = Off
Verbosity = Normal
|
Level: Off | Min | Max
Verbosity: Normal | None | Min | Max
|Debug
The default setting enables you to specify one of the following
Power-On-Self-Test (POST) behaviors to occur upon a routine system
power-on.
-
Level Off (default)– When enabled, POST will not run
upon routine system power-on.
Level Min – When enabled, the POST will run basic
diagnostic tests upon routine system power-on.
Level Max – When enabled, the POST will run basic
diagnostic tests and extensive processor and memory tests
upon routine system power-on.
-
Verbosity Normal – When enabled, a moderate amount
of debugging output to system console. Output includes test
name and results.
Verbosity None – When enabled, no debugging output
is printed to the system console.
Verbosity Min – When enabled, a limited amount of
debugging output is printed to the system console.
Verbosity Max – When enabled, all the POST step
debugging output is printed to system console.
Verbosity Debug – (The Debug setting is
no longer supported as of Oracle ILOM firmware version
3.2.6 or SPARC SW 9.7.x.) When enabled, an
extensive amount of debugging output is printed to system
console. Output includes the names of the devices being
tested, as well as the results of each test.
CLI Syntax Default Level and
Verbosity:
For a SPARC single-host server SP, type:
set /HOST/diag
default_level=off|min|max
default_verbosity=normal|none|min|max
For a SPARC multi-domain server SP, type:
set
/Servers/PDomains/PDomain_n/HOST/diag
default_level=off|min|max
default_verbosity=normal|none|min|max
|
Error Reset Level and Verbosity
(error_level=)
(error_verbosity=)
|
Level = Max
Verbosity = Normal
|
Level: Off | Max |Min
Verbosity: Normal | None | Min |
Max
Independently set a test level for each enabled trigger.
-
Level Max – When enabled, runs the maximum level of
diagnostic tests upon an error invoked reset.
Level Min – When enabled, runs the limited level of
diagnostic tests upon an error invoked reset.
Level Off – When Enabled, the POST will not run upon
an error invoked reset.
-
Verbosity Normal – When enabled, a moderate amount
of debugging output to system console. Output includes test
name and results.
Verbosity None – When enabled, no debugging output
is printed to the system console.
Verbosity Min – When enabled, a limited amount of
debugging output is printed to the system console.
Verbosity Max – When enabled, all the POST step
debugging output is printed to system console.
Verbosity Debug – When enabled, an extensive amount
of debugging output is printed to system console. Output
includes the names of the devices being tested, as well as
the results of each test.
CLI Syntax for Error Rest Level and
Verbosity:
For SPARC single-host server SP, type
set /HOST/diag
error_reset_level=off|min|max
verbosity_level=normal\none|min|max
For SPARC multi-domain server SP, type: set
Servers/PDomains/PDomain_n/HOST/diag
error_reset_level=off|min|max
verbosity_level=normal|none|min|max|debug
|
HW_Change Level and Verbosity
(hw_change_level=)
(hw_change_verbosity=)
|
Level = Max
Verbosity = Normal
|
Level: Off |Min |Max
Verbosity: None | Min | Max |
Debug
-
Level Max – When enabled, the POST will run the
maximum level of diagnostic tests in the event of a hardware
change such as a power cycle, chassis cover removal, or FRU
replacement.
Level Min – When enabled, the POST will run a
limited level of diagnostic tests in the event of a hardware
change such as a power cycle, chassis cover removal, or FRU
replacement.
Level Off – When Enabled, the POST will not run a
series of texts in the event of a hardware change such as a
power cycle, chassis cover removal, or FRU
replacement.
-
Verbosity Normal – When enabled, a moderate amount
of debugging output to system console. Output includes test
name and results.
Verbosity None – When enabled, no debugging output
is printed to the system console.
Verbosity Min – When enabled, a limited amount of
debugging output is printed to the system console.
Verbosity Max – When enabled, all the POST step
debugging output is printed to system console.
Verbosity Debug – (The Debug setting is no
longer supported as of Oracle ILOM firmware version
3.2.6 or SPARC SW 9.7.x.) When enabled, an
extensive amount of debugging output is printed to system
console. Output includes the names of the devices being
tested, as well as the results of each test.
CLI Syntax for Trigger
Verbosity:
For SPARC single-host server SP, type
set /HOST/diag/
hw_change_verbosity=normal|min|max|debug|none
hw_change_level=off|min|max
For SPARC multi-domain server SP, type:
set /Servers/PDomains/PDomain_n/HOST/diag
hw_change_level=off|min|max
hw_change_verbosity=normal|none|min|max|debug
|
|