Go to main content
Sun Storage 10 GbE FCoE ExpressModule Converged Network Adapter From QLogic Installation Guide For Adapter Models SG-EMFCOE2-Q-SR, SG-XEMFCOE2-Q-SR, SG-EMFCOE2-Q-TA, SG-XEMFCOE2-Q-TA, and 7101682

Exit Print View

Updated: January 2017
 
 

To Verify Attached Storage (Oracle SPARC Systems)

  • If online storage is connected to the Converged Network Adapter, use the show-children command to list the attached storage.

    Note - You might need to run the reset-all command before using the show-children command.

    In the following example, a RAID device shows one target and 10 LUNs attached to an FCoE switch connected to one port of a dual-port Converged Network Adapter.

    {0} ok show-disks
    a) /pci@7c0/pci@0/pci@8/SUNW,qlc@0,3/fp@0,0/disk
    b) /pci@7c0/pci@0/pci@8/SUNW,qlc@0,2/fp@0,0/disk
    c) /pci@7c0/pci@0/pci@1/pci@0,2/LSILogic,sas@2/disk
    d) /pci@7c0/pci@0/pci@1/pci@0/ide@8/cdrom
    e) /pci@7c0/pci@0/pci@1/pci@0/ide@8/disk
    q) NO SELECTION
    Enter Selection, q to quit: b
     
    {0} ok select /pci@7c0/pci@0/pci@8/SUNW,qlc@0,2 
    QLogic QEM8152  Host Adapter FCode(SPARC): 3.15 2013-01-11 19:29
    ISP Firmware version 5.03.02
    MPI FW version 1.39.00
     
    {0} ok show-children
    Adapter portID - 11401 
    ************** Fabric Attached Devices **************
     Dev# 0(0)   PortID 10500    Port WWN 200600a0b819e3b8
     LUN    0(0)    DISK  SUN     CSM100_R_FC     0619
     LUN    1(1)    DISK  SUN     CSM100_R_FC     0619
     LUN    2(2)    DISK  SUN     CSM100_R_FC     0619
     LUN    3(3)    DISK  SUN     CSM100_R_FC     0619
     LUN    4(4)    DISK  SUN     CSM100_R_FC     0619
     LUN    5(5)    DISK  SUN     CSM100_R_FC     0619
     LUN    6(6)    DISK  SUN     CSM100_R_FC     0619
     LUN    7(7)    DISK  SUN     CSM100_R_FC     0619
     LUN    8(8)    DISK  SUN     CSM100_R_FC     0619
     LUN    9(9)    DISK  SUN     CSM100_R_FC     0619