In the following example, a RAID device shows one target and 10 LUNs attached to an FCoE switch connected to one port of a dual-port Converged Network Adapter.
{0} ok show-disks
a) /pci@7c0/pci@0/pci@8/SUNW,qlc@0,3/fp@0,0/disk
b) /pci@7c0/pci@0/pci@8/SUNW,qlc@0,2/fp@0,0/disk
c) /pci@7c0/pci@0/pci@1/pci@0,2/LSILogic,sas@2/disk
d) /pci@7c0/pci@0/pci@1/pci@0/ide@8/cdrom
e) /pci@7c0/pci@0/pci@1/pci@0/ide@8/disk
q) NO SELECTION
Enter Selection, q to quit: b
{0} ok select /pci@7c0/pci@0/pci@8/SUNW,qlc@0,2
QLogic QEM8152 Host Adapter FCode(SPARC): 3.15 2013-01-11 19:29
ISP Firmware version 5.03.02
MPI FW version 1.39.00
{0} ok show-children
Adapter portID - 11401
************** Fabric Attached Devices **************
Dev# 0(0) PortID 10500 Port WWN 200600a0b819e3b8
LUN 0(0) DISK SUN CSM100_R_FC 0619
LUN 1(1) DISK SUN CSM100_R_FC 0619
LUN 2(2) DISK SUN CSM100_R_FC 0619
LUN 3(3) DISK SUN CSM100_R_FC 0619
LUN 4(4) DISK SUN CSM100_R_FC 0619
LUN 5(5) DISK SUN CSM100_R_FC 0619
LUN 6(6) DISK SUN CSM100_R_FC 0619
LUN 7(7) DISK SUN CSM100_R_FC 0619
LUN 8(8) DISK SUN CSM100_R_FC 0619
LUN 9(9) DISK SUN CSM100_R_FC 0619