Sun Flash Accelerator F40 PCIe Card Overview
About the Sun Flash Accelerator F40 PCIe Card
Card Software and Firmware Components
Preparing the Card for Installation
Perform ESD Prevention Measures
Update the Host Operating System
Installing the Card Into a Server
Remove an Existing Card From a Server
Servicing the Card Using the ddcli Utility
Show the Vital Product Data Command
Troubleshooting Using Card LEDs
The Sun Flash Accelerator F40 PCIe Card operates and is stored in an environment defined by the following parameters:
|
The Sun Flash Accelerator F40 PCIe Card is designed to provide continuous full bandwidth performance with flash disk temperatures up to 73 °C. Qualified host platforms with required software updates operate with sufficient margin to the maximum temperature under worst case environments.
Should the system maximum operating temperature be exceeded, or a system fault occur which causes internal temperatures of the flash disks to rise above this limit, the card responds as follows:
74 °C - Disk write throttling is engaged to reduce card power.
Card status LED yellow.
Temperature warning displays in ddcli -health output.
76 °C - Additional disk write throttling is engaged.
Card status LED red.
Critical temperature status displays in ddcli -health output.
Caution - Sustained critical temperatures may cause data loss. |
Note - For specific site planning guidelines and best practices, refer to the server site planning guide and product notes for your server.