Sun Flash Accelerator F40 PCIe Card Overview
About the Sun Flash Accelerator F40 PCIe Card
Card Software and Firmware Components
Preparing the Card for Installation
Perform ESD Prevention Measures
Update the Host Operating System
Installing the Card Into a Server
Remove an Existing Card From a Server
Servicing the Card Using the ddcli Utility
Access Text Menu Interface in ddcli Utility
Access Command Line Interface (CLI) in ddcli Utility
Show the Vital Product Data Command
Troubleshooting Using Card LEDs
The -locate command initates blinking on the Status LED of the selected Sun Flash Accelerator F40 PCIe Card. Use this command to locate a selected card in a rack of servers. The Status LED turns off after 60 seconds.
Text Menu Interface Usage: The following top-level menu lists the cards in the system and prompts you to select a card on which to perform an operation. Two Sun Flash Accelerator F40 PCIe Cards are shown in the following example:
# ddcli ID WarpDrive Package Version PCI Address -- --------- --------------- ----------- 1 ELP-4x100-4d-n 06.05.10.00 00:09:00:00 2 ELP-4x100-4d-n 06.05.10.00 00:05:00:00 Select the WarpDrive [1-2 or 0:Quit]: 1 1. List WarpDrive Information 2. Update Flash Package 3. Display WarpDrive Health 4. Locate WarpDrive 5. Format WarpDrive 6. Show Vital Product Data 7. Extract SMART Logs Select Operation [1-7 or 0:Quit]: 4 Enter Operation [1:on]:
Command Line Interface Usage: Enter the following line of text in the CLI to run the -locate command: ddcli -c 1 -locate on