Server Specifications
This section includes physical, electrical and environmental specifications for the
system.
Physical Specifications
The following table lists the physical specifications for the Sun Server X4-4.
|
|
Height
|
129.9 mm (5.1 inches)
|
Width
|
436.5 mm (17.2 inches)
|
Depth
|
732 mm (28.8 inches)
752.35 mm (29.6 inches) with PSU ejectors
|
Weight
|
40 kg (88 lbs)
|
|
Electrical Specifications
The following table lists the electrical specifications for the Sun Server X4-4.
|
|
Nominal input frequencies
|
50/60 Hz
|
Operating input voltage range
|
100-127 VAC (two-CPU configuration)
200-240 VAC (two or four-CPU configuration)
|
Rated input current
|
100-127 VAC 12A
200-240 VAC 10A
|
Maximum power consumption
|
2000W
|
Maximum heat output
|
6824 BTU/hr
|
|
Environmental Requirements
The following table lists the environmental requirements for the Sun Server X4-4.
|
|
Operating temperature (single, non-rack system)
|
At sea level: 5° C to 35° C
(41° F to 95° F)
At altitude: 5° C to 31° C
(41° F to 88° F)
|
Non-operating temperature (single, non-rack system)
|
-40° C to 68° C
(-40° F to 154° F)
|
Operating humidity (single, non-rack system)
|
10% to 90% relative humidity, non-condensing
|
Non-operating humidity (single, non-rack system)
|
Up to 93% relative humidity, non-condensing
|
Operating altitude (single, non-rack system)
|
Up to 3,000 m (9,840 ft), maximum ambient temperature is derated by 1 degree C per 300m above
900 m, except in China where regulations might limit installations to a maximum altitude of 2,000
m
|
Non-operating altitude (single, non-rack system)
|
0 m to 12,000 m (0 ft to 40,000 ft)
|
Acoustic noise
|
LwAd: 8.9 B (idle and operating, room temp.), 8.9 B (max. ambient); LpAm: 75 dBA (bystander
position, max. ambient)
|
|