Cluster Interconnect Technologies

The following table lists example node-to-node link technologies and their limitations.

Table 7-2  Campus Cluster Interconnect Technologies and Distance Limits
Link Technology
Maximum Distance
Comments
100 Mbps Ethernet
100 meters per segment
Unshielded twisted pair (UTP)
1000 Mbps Ethernet
100 meters per segment
UTP
1000 Mbps Ethernet
260 meters per segment
62.5/125 micron multimode fiber (MMF)
1000 Mbps Ethernet
550 meters per segment
50/125 micron MMF
1000 Mbps Ethernet (FC)
10 kilometers at 1 Gbps
9/125 micron single-mode fiber (SMF)
DWDM
200 kilometers and up
Other
Consult your Oracle representative