Go to main content

Oracle® Exadata Storage Server X5-2 Extreme Flash Service Manual

Exit Print View

Updated: January 2018
 
 

Remove the Left LED Indicator Module

  1. Prepare the storage server for service.
    1. Power off the storage server and disconnect the power cords from the power supplies.

      See Powering Down the Storage Server.

    2. Extend the storage server into the maintenance position.

      See Extend the Storage Server to the Maintenance Position.

    3. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.

      See Take Antistatic Measures.

    4. Remove the storage server top cover.

      See Remove the Storage Server Top Cover.

  2. Remove the storage server fan assembly door.

    See Remove the Fan Assembly Door From the Storage Server.

  3. Remove the four remaining No. 2 Phillips screws (two on each side of the chassis) that secure the disk cage assembly to the storage server chassis.
    image:Figure showing the removal of the disk cage assembly screws.
  4. Remove the fan modules from the storage server.

    See Remove a Fan Module.

  5. Disconnect all cables from the storage drive backplane.

    See Remove the Storage Drive Backplane.

  6. Disconnect the left LED indicator module cable and the right LED/USB indicator module cable from the motherboard [1 and 2].
    image:Figure showing the removal of the disk cage assembly from the server                         chassis.
  7. Slide the disk cage assembly forward, and then gently lift the disk cage assembly from the chassis [3].

    Set the disk cage assembly on an anti-static mat.

  8. Remove the left LED indicator module.
    1. Remove the two No. 2 Phillips screws that secure the LED indicator module to the storage server front panel [1].

      If present, remove the capping tape that secures the cable to the side of the disk cage assembly.


      image:Figure showing the removal of the left LED indicator                               module.
    2. Remove the LED indicator module from the server front panel [2].

Related Information