Server Specifications
This section includes physical, electrical and environmental specifications for the
system.
Physical Specifications
The following table lists the physical specifications for the Oracle Server X5-8:
|
|
Height
|
5U / 219.25 mm (8.63 in.)
|
Width
|
445 mm (17.5 in.)
|
Depth
|
834 mm (32.8 in.)
|
Weight
|
114 kg (250 lbs)
|
|
Electrical Specifications
The following table lists the electrical specifications for the Oracle Server
X5-8:
|
|
Nominal input frequencies
|
50/60 Hz
|
Operating input voltage range
|
200-240 VAC
|
Rated input current
|
23A @ 200 to 230 VAC
12A max per cord
|
Maximum power consumption
|
3400 W
|
Maximum heat output
|
11600 BTU/Hr
|
|
Environmental Requirements
The following table lists the environmental requirements for the Oracle Server
X5-8:
|
|
Operating temperature (single, non-rack system)
|
At sea level: 5° C to 35° C (41° F to 95° F)
At altitude: 5° C to 31° C (41° F to 88° F)
|
Operating temperature
|
5° C to 35° C (4° F to 95° F)
|
Non-operating temperature
|
-40 °C to 70 °C (-40 °F to 158° F)
|
Operating humidity
|
10% to 90% relative humidity, non-condensing
|
Non-operating humidity
|
Up to 93% relative humidity, non-condensing
|
Operating altitude
|
Up to 3,000 m (9,840 ft), maximum ambient temperature is
derated by 1 degree C per 300 m above 900 m, except in China
where regulations may limit installations to a maximum altitude
of 2,000 m
|
Non-operating altitude
|
0 m to 12,000 m (0 ft to 40,000 ft)
|
Acoustic noise
|
Acoustic noise: 7.7 B operating, 6.8 B idling - (LwAd: 1 B=10
dB)
|
|