未解决问题的显示
对于每个问题,设备将报告发生的问题、检测到该问题的时间、该问题的严重性和类型,以及是否已将其回拨。以下是 BUI 中可能会显示的一些故障示例:
表 1-9 BUI 问题的显示示例 | | | |
---|
2009-09-16 13:56:36 | SMART health-monitoring firmware reported that a disk failure is imminent.(SMART 运行状况监视固件报告了即将发生磁盘故障。) | Major Fault(重大故障) | Never(从不) | 2009-09-05 17:42:55 | A disk of a different type (cache, log, or data) was inserted into a slot.The newly inserted device must be of the same type.(不同类型(高速缓存、日志或数据)的磁盘插入到插槽。新插入设备的类型必须相同。) | Minor Fault(轻微故障) | Never(从不) | 2009-08-21 16:40:37 | The ZFS pool has experienced currently unrecoverable I/O failures.(ZFS 池遇到当前不可恢复的 I/O 故障。) | Major Error(重大错误) | Never(从不) | 2009-07-16 22:03:22 | A memory module is experiencing excessive correctable errors affecting large numbers of pages.(内存模块遇到过多可纠正错误,从而影响大量页面。) | Major Fault(重大故障) | Never(从不) |
|
也可以在 CLI 中查看此类信息:
gefilte:> maintenance problems show
Problems:
COMPONENT DIAGNOSED TYPE DESCRIPTION
problem-000 2010-7-27 00:02:49 Major Fault SMART health-monitoring
firmware reported that a
failure is imminent on disk
'HDD 17'.
选择任一故障均可显示有关该故障的详细信息,包括对系统的影响、受影响的组件、系统的自动响应(如果有),以及建议管理员执行的操作(如果有)。在 CLI 中,只有 "uuid"、"diagnosed"、"severity"、"type" 和 "status" 字段可视为稳定字段。其他属性值可能会随着版本的不同而改变。
对于硬件故障,您可以选择受影响的硬件组件以便在 "Maintenance"(维护)> "Hardware"(硬件)屏幕上定位该组件。