使用 CLI 通过以下过程定位出现故障的组件。
hostname:> maintenance hardware
hostname:maintenance hardware> list
             NAME        STATE       MODEL             SERIAL      
chassis-000  hostname    ok          Sun Storage 7320  unknown     
chassis-001  000000000C  faulted     J4410             000000000C  
hostname:maintenance hardware> select chassis-001
hostname:maintenance chassis-001> list
                         disk
                          fan
                          psu
                         slot
hostname:maintenance chassis-001> select disk
hostname:maintenance chassis-001 disk> show
Disks:
          LABEL   STATE       MANUFACTURER  MODEL             SERIAL      
disk-000  HDD 0   ok          ST3500630NS   ST3500630NS       9QG1ACNJ    
disk-001  HDD 1   faulted     ST3500630NS   ST3500630NS       9QG1A77R    
disk-002  HDD 2   ok          ST3500630NS   ST3500630NS       9QG1AC3Z    
disk-003  HDD 3   ok          ST3500630NS   ST3500630NS       9QG1ACKW    
disk-004  HDD 4   ok          ST3500630NS   ST3500630NS       9QG1ACKF    
disk-005  HDD 5   ok          ST3500630NS   ST3500630NS       9QG1ACPM    
disk-006  HDD 6   ok          ST3500630NS   ST3500630NS       9QG1ACRR    
disk-007  HDD 7   ok          ST3500630NS   ST3500630NS       9QG1ACGD    
disk-008  HDD 8   ok          ST3500630NS   ST3500630NS       9QG1ACG4    
disk-009  HDD 9   ok          ST3500630NS   ST3500630NS       9QG1ABDZ    
disk-010  HDD 10  ok          ST3500630NS   ST3500630NS       9QG1A769    
disk-011  HDD 11  ok          ST3500630NS   ST3500630NS       9QG1AC27    
disk-012  HDD 12  ok          ST3500630NS   ST3500630NS       9QG1AC41    
disk-013  HDD 13  ok          ST3500630NS   ST3500630NS       9QG1ACQ5    
disk-014  HDD 14  ok          ST3500630NS   ST3500630NS       9QG1ACKA    
disk-015  HDD 15  ok          ST3500630NS   ST3500630NS       9QG1AC5Y    
disk-016  HDD 16  ok          ST3500630NS   ST3500630NS       9QG1ACQ2    
disk-017  HDD 17  ok          ST3500630NS   ST3500630NS       9QG1A76S    
disk-018  HDD 18  ok          ST3500630NS   ST3500630NS       9QG1ACDY    
disk-019  HDD 19  ok          ST3500630NS   ST3500630NS       9QG1AC3Y    
disk-020  HDD 20  ok          ST3500630NS   ST3500630NS       9QG1ACG6    
disk-021  HDD 21  ok          ST3500630NS   ST3500630NS       9QG1AC3X    
disk-022  HDD 22  ok          ST3500630NS   ST3500630NS       9QG1ACHL    
disk-023  HDD 23  ok          ST3500630NS   ST3500630NS       9QG1ABLW    
hostname:maintenance chassis-001 disk> select disk-001
hostname:maintenance chassis-001 disk-001> set locate=true
                       locate = true (uncommitted)
hostname:maintenance chassis-001 disk-001> commit