Fan Events
The following table lists fan events.
|
|
SNMP Trap:
sunHwTrapFanSpeedCritThresholdExceeded
Oracle ILOM Event Message: Lower
critical threshold exceeded
Severity and Description: Major; A fan
speed sensor has reported that its value has gone above an upper critical
threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an
upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-1]/TACH
|
SNMP Trap:
sunHwTrapFanSpeedCritThresholdDeasserted
Oracle ILOM Event Message: Lower
critical threshold no longer exceeded
Severity and Description:
Informational; A fan speed sensor has reported that its value has
gone below an upper critical threshold setting or above a lower critical
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an
upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-1]/TACH
|
SNMP Trap:
sunHwTrapFanSpeedFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal
threshold exceeded
Severity and Description: Critical; A
fan speed sensor has reported that its value has gone above an upper fatal
threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an
upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-1]/TACH
|
SNMP Trap:
sunHwTrapFanSpeedFatalThresholdDeasserted
Oracle ILOM Event Message: Lower fatal
threshold no longer exceeded
Severity and Description:
Informational; A fan speed sensor has reported that its value has gone below
an upper fatal threshold setting or above a lower fatal threshold
setting.
The sunHwTrapThresholdType object indicates whether the threshold was an
upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-1]/TACH
|
|