Go to main content

Oracle® ILOM Protocol Management Reference SNMP and IPMI Firmware Release 4.0.x

Exit Print View

Updated: August 2017
 
 

Display Sensor List

  • To view a list of sensors on a managed device, type:
    $ ipmitool -I [orcltls|lanplus] -H SP_hostname_or_IPaddress -U username -P password
    sdr list

    Note -  The IPMI TLS interface ( orcltls) is supported as of Oracle ILOM firmware version 3.2.8 and later. For a higher level of security, you should always specify the IPMI TLS interface (-I orcltls) when executing Oracle ILOM commands from the IMPItool utility. For more information about using the IPMI TLS interface from Oracle, see these topics:IPMI TLS Service and Interface and Configure IPMI Management Access for Increased Security in Oracle ILOM Security Guide For Firmware Releases 3.x and 4.x.

    The output might look like the following:

    /SYS/T_AMB       | 24 degrees C 		 	 	| ok
    /RFM0/FAN1_SPEED | 7110 RPM          | ok
    /RFM0/FAN2_SPEED | 5880 RPM          | ok
    /RFM1/FAN1_SPEED | 5880 RPM          | ok
    /RFM1/FAN2_SPEED | 6360 RPM          | ok
    /RFM2/FAN1_SPEED | 5610 RPM          | ok
    /RFM2/FAN2_SPEED | 6510 RPM          | ok
    /RFM3/FAN1_SPEED | 6000 RPM          | ok
    /RFM3/FAN2_SPEED | 7110 RPM          | ok
    /RFM4/FAN1_SPEED | 6360 RPM          | ok
    /RFM4/FAN2_SPEED | 5610 RPM          | ok
    /RFM5/FAN1_SPEED | 5640 RPM          | ok
    /RFM5/FAN2_SPEED | 6510 RPM          | ok
    /RFM6/FAN1_SPEED | 6180 RPM          | ok
    /RFM6/FAN2_SPEED | 6000 RPM          | ok
    /RFM7/FAN1_SPEED | 6330 RPM          | ok
    /RFM7/FAN2_SPEED | 6330 RPM          | ok
    /RFM8/FAN1_SPEED | 6510 RPM          | ok
    /RFM8/FAN2_SPEED | 5610 RPM          | ok
    

    Note -  The sensor output shown in the preceding example was shortened. The actual output will depend on the hardware platform.