Remove a DIMM


Caution

Caution  - These procedures require that you handle components that are sensitive to ESD. This sensitivity can cause the component to fail. To avoid damage, ensure that you follow antistatic practices as described in ESD Measures.


You can perform this procedure. The system must be completely powered down before performing this procedure. See Component Service Categories for more information about cold-service procedures.

Perform this procedure to remove a faulty DIMM from the motherboard.

  1. Locate the DIMM to be removed.

    See Locate a Failed DIMM (LEDs) and Locate a Failed DIMM (Oracle ILOM).

  2. Remove the faulty DIMM.
    1. Press down both DIMM slot ejector tabs as far as they can go.
    2. Carefully lift the DIMM straight up.

    Caution

    Caution  - Whenever you remove a DIMM, you should replace it with another DIMM before applying power to the server. Otherwise, the server might overheat due to improper airflow.