Ethernet Management Switch Cabling Reference
The Ethernet management switch is located in the storage rack in U21.
|
|
|
|
1 |
Indicators
and reset switch |
4 |
Ports 33-48, 10/100/1000BASE-T Ethernet |
2 |
Ports 1 to 16, 10/100/1000BASE-T Ethernet |
5 |
CON (upper), MGT (lower) |
3 |
Ports 17 to 32, 10/100/1000BASE-T Ethernet |
6 |
Ports 45-48,
10GbE |
|
When the table lists Compute server 0 or 1, choose the server that has a GbE NIC
in the specified IOU.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
Compute server
0, IOU 2 or Compute server 1, IOU 0 |
GbE |
PCIe 3 |
0 |
20 ft blue |
|
2 |
Compute server
0, IOU 3 or Compute server 1, IOU 1 |
GbE |
PCIe 3 |
3 |
20 ft blue |
|
3 |
Compute server
0, IOU 1 |
GbE |
PCIe 3 |
3 |
20 ft blue |
|
4 |
Compute server 0, IOU 3 or Compute server
1, IOU 1 |
GbE |
PCIe 3 |
2 |
20 ft blue |
|
5 |
Compute server 0, IOU 1 |
GbE |
PCIe 3 |
2 |
20 ft
blue |
|
6 |
Compute server 0, IOU 3 or Compute server 1, IOU 1 |
GbE |
PCIe 3 |
1 |
20 ft
blue |
|
7 |
Compute server 0, IOU 1 |
GbE |
PCIe 3 |
1 |
20 ft blue |
|
8 |
Compute server 0, IOU 3
or Compute server 1, IOU 1 |
GbE |
PCIe 3 |
0 |
20 ft blue |
|
9 |
Compute server 0, IOU 1 |
GbE |
PCIe
3 |
0 |
20 ft blue |
|
10 |
Compute server 0, IOU 2 or Compute server 1, IOU 0 |
GbE |
PCIe
3 |
3 |
20 ft blue |
|
11 |
Compute server 0, IOU 0 |
GbE |
PCIe 3 |
3 |
20 ft blue |
|
12 |
Compute server 1 |
SP
1 |
|
NET MGT |
20 ft red |
|
13 |
Compute server 0, IOU 0 |
GbE |
PCIe 3 |
2 |
20 ft blue |
|
14 |
Compute server
1 |
SP 0 |
|
NET MGT |
20 ft red |
|
15 |
Compute server 0, IOU 0 |
GbE |
PCIe 3 |
1 |
20 ft blue |
X |
16 |
Storage
rack |
PDU A |
|
NET MGT |
1m gray |
|
17 |
Compute server 0, IOU 0 |
GbE |
PCIe 3 |
0 |
20 ft blue |
|
18 |
Compute server
0 |
SP 1 |
|
NET MGT |
20 ft red |
|
19 |
Storage rack |
ZFS storage controller 2 |
U26 |
NET 1 |
10 ft black |
X |
20 |
Storage
rack |
PDU B |
|
NET MGT |
1m gray |
|
21 |
Storage rack |
ZFS storage controller 2 |
U26 |
NET 0 |
10 ft black |
|
22 |
Compute server
0 |
SP 0 |
|
NET MGT |
20 ft red |
|
23 |
Storage rack |
ZFS storage controller 1 |
U25 |
NET 1 |
10 ft black |
|
24 |
Compute
server 0, IOU 2 or Compute server 1, IOU 0 |
GbE |
PCIe 3 |
1 |
20 ft blue |
X |
25 |
Storage
rack |
Storage server |
U18 |
NET 0 |
10 ft black |
X |
26 |
Storage rack |
Storage server |
U18 |
NET MGT |
10 ft red |
|
27 |
Storage rack |
ZFS storage
controller 1 |
U25 |
NET 0 |
10 ft black |
|
28 |
Compute server 0, IOU 2 or Compute server 1,
IOU 0 |
GbE |
PCIe 3 |
2 |
20 ft blue |
X |
29 |
Storage rack |
Storage server |
U16 |
NET 0 |
10 ft black |
X |
30 |
Storage rack |
Storage server |
U16 |
NET
MGT |
10 ft red |
X |
31 |
Storage rack |
Storage server |
U14 |
NET 0 |
10 ft black |
X |
32 |
Storage rack |
Storage server |
U14 |
NET MGT |
10 ft
red |
X |
33 |
Storage rack |
Storage server |
U12 |
NET 0 |
10 ft black |
X |
34 |
Storage rack |
Storage server |
U12 |
NET MGT |
10 ft red |
X |
35 |
Storage rack |
Storage
server |
U10 |
NET 0 |
10 ft black |
X |
36 |
Storage rack |
Storage server |
U10 |
NET MGT |
10 ft red |
X |
37 |
Storage rack |
Storage server |
U8 |
NET 0 |
10
ft black |
X |
38 |
Storage rack |
Storage server |
U8 |
NET MGT |
10 ft red |
X |
39 |
Storage rack |
Storage server |
U6 |
NET 0 |
10 ft black |
X |
40 |
Storage
rack |
Storage server |
U6 |
NET MGT |
10 ft red |
X |
41 |
Storage rack |
Storage server |
U4 |
NET 0 |
10 ft black |
X |
42 |
Storage rack |
Storage server |
U4 |
NET
MGT |
10 ft red |
X |
43 |
Storage rack |
Storage server |
U2 |
NET 0 |
10 ft black |
X |
44 |
Storage rack |
Storage server |
U2 |
Net MGT |
10 ft
red |
X |
45 |
Storage rack |
IB leaf switch 2 |
U22 |
NET MGT 0 |
10 ft black |
X |
46 |
Storage rack |
IB leaf switch
1 |
U20 |
NET MGT 0 |
10 ft black |
X |
47 |
Storage rack |
IB spine switch |
U1 |
NET MGT 0 |
10 ft black |
|
48 |
Client
access LAN
Note - Do not connect until you ensure that there are no IP address
conflicts.
|
|
|
|
10” blue |
|
Related Information