Environmental Specifications

The HBA environmental requirements are listed in Figure 4, Table 4, HBA Environmental Specifications.

Table 4  HBA Environmental Specifications
Specification
Operating
Non-Operating
Temperature
10 °C to 55 °C, non-condensing
-40 °C to 70 °C, non-condensing
Humidity
20% to 80% RH, non-condensing, 40 °C max, 27 °C max wet bulb, 16 hour dwells at extreme
5% to 90% RH, non-condensing, 38 °C max wet bulb
Altitude
3000m at 40 °C, 4 hour dwell
12,000m at 0 °C, 4 hour dwell
Vibration
0.20G in all axes swept for 5-500 Hz, 5 sweeps in all at 1 octave/min
1.0G in all axes swept for 5-500 Hz, 5 sweeps in all at 1 octave/min
Shock
5G, 11 ms half-sine
30G, 11 ms half-sine
Airflow
At least 200 linear feet per minute (LFPM) to avoid operating the HBA processor above the ambient temperature
At least 200 linear feet per minute (LFPM)