Install a Drive or Drive Filler

Installing a drive into a server is a two-step process. You must first install the drive into the drive slot and then configure that drive to the server.


Note - If you removed an existing drive from a slot in the server, you must install the replacement drive in the same slot as the drive that was removed. Drives are physically addressed according to the slot in which they are installed.
  1. Remove a drive or a drive filler.

    See Remove a Drive or Drive Filler.

  2. Unpack the drive and place it on an antistatic mat.
  3. Fully open the release lever on the drive.
  4. Install the drive or drive filler by completing the following tasks.
    image:Figure showing how to insert a drive or drive filler.
    1. Slide the drive or drive filler into the drive slot until it is fully seated.
    2. Close the latch to lock the drive or drive filler in place.
  5. Return the drive to operation by doing one of the following tasks:
    • If you cold-serviced the drive, restore power to the server. Complete the procedure described in Power On the Server (Oracle ILOM) or Power On the Server (System Power Button).
    • If you hot-serviced the drive, configure it using the cfgadm -c configure command. The following example shows the drive at c0::dsk/c1t1d0 being configured.
      # cfgadm -c configure c0::dsk/c1t1d0
      

      Replace c0:dsk/c1t1d0 with the drive name that applies to your situation.

    • If you hot-serviced an NVMe drive, it should automatically power up and attach. If not, power up and attach the drive manually.
      # hotplug enable /SYS/DBP/NVME0

      Check that the drive's state has changed to ENABLED.

      # hotplug list –lc
  6. Verify the drive functionality.

    See Verify a Drive.