Install a Drive or Drive Filler
Installing a drive into a server is a two-step
process. You must first install the drive into the drive slot and
then configure that drive to the server.
Note - If you removed an existing drive from a slot in the
server, you must install the replacement drive in the same slot
as the drive that was removed. Drives are physically addressed according
to the slot in which they are installed.
- Remove
a drive or a drive filler.
See Remove a Drive or Drive Filler.
- Unpack the drive and place it
on an antistatic mat.
- Fully open the release lever
on the drive.
- Install the drive or drive filler by completing the following tasks.
- Slide the drive or drive filler into
the drive slot until it is fully seated.
- Close the latch to lock the drive or drive filler in place.
- Return the drive to operation by doing one of the following tasks:
- If you cold-serviced
the drive, restore power to the server. Complete the procedure described
in Power On the Server (Oracle ILOM) or Power On the Server (System Power Button).
- If you hot-serviced the drive,
configure it using the cfgadm -c configure command.
The following example shows the drive at c0::dsk/c1t1d0 being configured.
# cfgadm -c configure c0::dsk/c1t1d0
Replace c0:dsk/c1t1d0 with the drive name
that applies to your situation.
-
If you hot-serviced an NVMe drive, it should automatically power up
and attach. If not, power up and attach the drive manually.
# hotplug enable /SYS/DBP/NVME0
Check that the drive's state has changed to ENABLED.
# hotplug list –lc
- Verify the drive functionality.
See Verify a Drive.