Go to main content
Oracle® Fabric Interconnect F2-12 Service Manual

Exit Print View

Updated: November 2016
 
 

Perform Additional Diagnostics at the Switch

  1. Are you starting a new troubleshooting session with this task?
  2. Is the chassis status amber Attention LED on to indicate a fault?
  3. Is a fan module amber Attention LED on?
  4. Fully depress the green release button and unseat the faulted fan module, wait a minute, then reseat the fan module.
  5. Does the fan module Attention LED persist?
  6. Are black-colored PrizmMT cables connected in ports 1 through 4?
    • Yes – Go to Step 8.
    • No – Reattach the black-colored PrizmMT cables to ports 1 through 4, then go to Step 8.
  7. Are magenta-colored PrizmMT or aqua-colored standard MT cables connected in ports 5 and 6?
    • Yes – Go to Step 6.
    • No – Reattach the magenta-colored PrizmMT or aqua-colored standard MT cables to ports 5 and 6, then go to Step 6.
  8. Are all cabled Ethernet port Link LEDs on?
  9. Does any cabled Ethernet port Link LED flash on occasion?
  10. Are you sure you know that the cabling for the suspect ports is wired correctly with good cables and firm connections?
  11. Inspect and replace cabling as necessary.

    Then return to Step 8.

  12. Are you sure you know that the communication hardware (NICs, hosts, routers, and switches) are fully functional?
    • Yes – The switch itself is defective. Go to Step 14.
    • No – Go to Step 13.
  13. Inspect and replace communication hardware as necessary.

    Then return to Step 8.

  14. Remove the faulted component and install a new component.

    See Faulted Item Replaceable Components for links to service tasks.

  15. Perform further diagnostics.

    See Perform Diagnostics Remotely.

Related Information