Touch Layout

The following program description deals with:


General Short Description of the whole Layout Design

To the standard  touch screen layout for the screen-based terminals (touch screens) you can add other layouts, design them individually (including the free key alignment) and adjust them to the local requirements.

Adjustment means:

Notes:


Remarks on the Program Function

Go to System -> User Interface -> Touch Layout.

The general layout and the linked screen pages are defined with this update program, i.e. the height and width and the number of columns and rows for the function key concerned. The general layout for the screen pages of the following screens is defined via the defaults in field "Layout type". This setting has priority over the values in fields Height, Width, Columns, Rows.

Layout type

Description

Non POS 30

All touch layouts without coding "_30", "_30L" and "_30LH".

POS 30

All touch layouts with coding "_30" and "_30H" and _30FH". (30L = 35 keys, 30F = 54 keys)

POS 30 large

All touch layouts with coding "_30L" and "_30LH".

POS 30 Pocket

All touch layouts with coding "PocketPC".

POS 40 large

All touch layouts with coding " Layout_40". (= Resolution 1024 und 1152).
Note:
The layout for this touch screen POS can be configured via button "Add.data" with additional parameters.

These values can, however, be changed in program Touch Page and the update program Layout program. In addition, you give the new layout a unique number. The touch layout consists of one or more layout pages and touch keys.

Attention!
The following standard layouts have been programmed under Numbers 1 to 25 for the appropriate Terminal programs .

No.

Layout name

1

Standard layout

2

Fast Food layout

3

Big layout

4

PocketPC layout

5

PocketPC layout_H

6

Big layoutXA

7

Layout_40_1024

8

Layout_40_1152

10

Standard layout_30

11

Standard Layout_30L

12

Std layout_30XA

13

Std Layout_30LXA

14

Std layout_30XB

15

Std Layout_30LXB

20

Standard layout_30H

21

Standard Layout_30LH

22

Std layout_30HXA

23

Std Layout_30LHXA

24

Std layout_30HXB

25

Std Layout_30LHXB

 

If a new layout is required, the copy procedure can be applied, i.e. a standard layout is selected and this is duplicated with Process -> Copy -> Object tree (description see Touch Screen Layout Configuration). As the standard layout returns to the old values after every "UiSales.fgl" and "dofgl.fgl" and thus after every release change, it is important that the new layout should be programmed under its own unique free layout no..

 

Adding new screen pages to the existing layout is done with button "Create page" in program Touch Page. After clicking on this button in the program, you can create a screen page that corresponds to the layout type you defined in the program Touch Layout.


Remarks on the Input Fields

This paragraph will provide a short overview over the options available for updating these basic data

Just like in almost any other program:


Touch Layout

Permitted input range: numeric, 1 - 99

Every new touch layout you create has to be stored with a free unique number.

The standard layouts listed below are stored under numbers 1 to 25 for the appropriate Terminal programs.

No.

Layout name

1

Standard layout

2

Fast Food layout

3

Big layout

4

PocketPC layout

5

PocketPC layout_H

6

Big layoutXA

7

Layout_40_1024

8

Layout_40_1152

10

Standard layout_30

11

Standard Layout_30L

12

Std layout_30XA

13

Std Layout_30LXA

14

Std layout_30XB

15

Std Layout_30LXB

20

Standard layout_30H

21

Standard Layout_30LH

22

Std layout_30HXA

23

Std Layout_30LHXA

24

Std layout_30HXB

25

Std Layout_30LHXB

You can make changes or deletions by entering the number of the layout and confirming it. The data record linked to the number will be displayed.

This number is also entered in the program Terminals in field "Touch Layout" By this, the touch layout will be assigned to the terminal.

Linkage of the touch layouts to the terminal programs can be found in the documentation Terminal program / Touch layout.


Descriptor

Permitted input range: alphanumeric, max. 20 chars.

When creating a new record, enter a free eloquent name here. The standard layouts listed below are stored under numbers 1 to 25 for the appropriate Terminal programs.

No.

Layout name

1

Standard layout

2

Fast Food Layout

3

Big layout

4

PocketPC layout

5

PocketPC layout_H

6

Big layoutXA

7

Layout_40_1024

8

Layout_40_1152

10

Standard layout_30

11

Standard Layout_30L

12

Std layout_30XA

13

Std Layout_30LXA

14

Std layout_30XB

15

Std Layout_30LXB

20

Standard layout_30H

21

Standard Layout_30LH

22

Std layout_30HXA

23

Std Layout_30LHXA

24

Std layout_30HXB

25

Std Layout_30LHXB

Linkage of the touch layouts to the terminal programs can be found in the documentation Terminal program / Touch layout.


Event Name

Permitted input range: alphanumeric, max. 20 chars.

This field is reserved for entry of the key event with which the keys of the linked touch pages are linked. The real function for the individual key is programmed under "Layout Prg." in program Touch pages.

A list of the names can be found in the documentation Key and booking functions. For example DEPT should be entered to record a department. The next touch page is called up from entry fTP for example.


Def. Width

Permitted input range: numeric, 0 - 999

Here you define the width of a screen key. The unit is Pixel (image points).

The standard width of a key is 54 Pixel.

Note:
Please note that the values for defaults of the touch layout are defined mainly by the entry in field "Layout Type". The values for width, height, lines and columns only applies to screen layouts for which the entry "Non POS 30" has been selected in field "Layout Type".

The general layout for the touch pages of the following terminal screens is defined with the default in field "Layout Type". This setting has priority over the values in fields height, width, columns and rows.

Layout type

Description

Non POS 30

All touch layouts without coding "_30", "_30L" and "_30LH".

POS 30

All touch layouts with coding "_30" and "_30H" and _30FH". (30L = 35 keys, 30F = 54 keys)

POS 30 large

All touch layouts with coding "_30L" and "_30LH".

POS 30 Pocket

All touch layouts with coding "PocketPC".

POS 40 large

All touch layouts with coding " Layout_40". (= Resolution 1024 und 1152).
Note:
The layout for this touch screen POS can be configured via button "Add.data" with additional parameters.


Def. Height

Permitted input range: numeric, 0 - 999

Here you define the height of a screen key. The unit is Pixel (image points).

The standard height of a key is 54 Pixel.

Note:
Please note that the values for defaults of the touch layout are defined mainly by the entry in field "Layout Type". The values for width, height, lines and columns only applies to screen layouts for which the entry "Non POS 30" has been selected in field "Layout Type".

The general layout for the touch pages of the following terminal screens is defined with the default in field "Layout Type". This setting has priority over the values in fields height, width, columns and rows.

Layout type

Description

Non POS 30

All touch layouts without coding "_30", "_30L" and "_30LH".

POS 30

All touch layouts with coding "_30" and "_30H" and _30FH". (30L = 35 keys, 30F = 54 keys)

POS 30 large

All touch layouts with coding "_30L" and "_30LH".

POS 30 Pocket

All touch layouts with coding "PocketPC".

POS 40 large

All touch layouts with coding " Layout_40". (= Resolution 1024 und 1152).
Note:
The layout for this touch screen POS can be configured via button "Add.data" with additional parameters.


Def. Spacing

Permitted input range: numeric, 0 - 99

In this field you define the width of the key edge. The unit is Pixel (image points).

The size of the standard key is 54 x 54 Pixel. The default value of the edge is 1st Two Pixel (1 Pixel per key) is the minimum value to be able to separate two keys optically from each other.


Language

The linked language is shown in this field. The touch layout is generated for the language concerned from command "oscar dofgl.fgl Language".


Resolution

The resolution of the touch layout is shown in this field.


Fore. Color

Permitted input range: numeric, 1 - 9999

NOTE!
The foreground colour of the buttons can only be changed for touch layouts "Non PoS 30".  The touch keys of the layout type "Pos 30*" consist of bitmaps. The colour cannot be changed.

Via this parameter, you define the color of the foreground. The MICROS Retail OSCAR POS application is already delivered with a standard pre-selection. Alternatively, you can also select other foreground and background:colors.

The Color table shows the link of each color to a color no. and also the name of the color.

Via the button on the right, you can also enter the window for the maintenance of the Colors. There you can mix your own colors by entering the various color parts (red, green, blue).


Back. Color

Permitted input range: numeric, 1 - 9999

NOTE!
The background colour of the buttons can only be changed for touch layouts "Non PoS 30".  The touch keys of the layout type "Pos 30*" consist of bitmaps. The colour cannot be changed. Here you define the background color of the screen. You can select the settings the operating system suggests or define one of the preset colors – depending on the selected foreground color.

The Color table shows the link of each color to a color no. and also the name of the color.

Via the button on the right, you can also enter the window for the maintenance of the Colors. There you can mix your own colors by entering the various color parts (red, green, blue).


Def. Font

Permitted input range: numeric, 1 - 999

Here you define the default value of the key font. The standard size is 12 points. You can overwrite this value to change the standard font size, or you can keep the standard value and change the Key Layout in single pages only.

Via the button on the right, you can enter the window for the maintenance of the Fonts. There you can create new fonts and define the font layout.

Notes:


Def. Columns

Permitted input range: numeric

Here you define how many key columns (vertical key alignment) are to be displayed on the screen. The maximum number is 5, at the same time this is the default value. You can overwrite it with a smaller number.

Note:
Please note that the values for the defaults of the touch layout are mainly dependent on the entry in field "Layout Type". The values for width, height, rows and columns applies only to touch layouts to which the entry "Non POS 30" has been linked in field "Layout Type".

The general layout of the touch pages of the following touch screens is defined by the defaults in field "Layout Type". The setting has priority over the values entered in fields Height, Width, Columns, Rows.

Layout type

Description

Non POS 30

All touch layouts without coding "_30", "_30L" and "_30LH".

POS 30

All touch layouts with coding "_30" and "_30H" and _30FH". (30L = 35 keys, 30F = 54 keys)

POS 30 large

All touch layouts with coding "_30L" and "_30LH".

POS 30 Pocket

All touch layouts with coding "PocketPC".

POS 40 large

All touch layouts with coding " Layout_40". (= Resolution 1024 und 1152).
Note:
The layout for this touch screen POS can be configured via button "Add.data" with additional parameters.


Def. Rows

Permitted input range: numeric

Analogous to the number of the key columns, you can also define the number of the key rows (horizontal key alignment) to be displayed on the screen. The maximum number is 8. You can decrease the number.

Note:
Please note that the values for the defaults of the touch layout are mainly dependent on the entry in field "Layout Type". The values for width, height, rows and columns applies only to touch layouts to which the entry "Non POS 30" has been linked in field "Layout Type".

The general layout of the touch pages of the following touch screens is defined by the defaults in field "Layout Type". The setting has priority over the values entered in fields Height, Width, Columns, Rows.

Layout type

Description

Non POS 30

All touch layouts without coding "_30", "_30L" and "_30LH".

POS 30

All touch layouts with coding "_30" and "_30H" and _30FH". (30L = 35 keys, 30F = 54 keys)

POS 30 large

All touch layouts with coding "_30L" and "_30LH".

POS 30 Pocket

All touch layouts with coding "PocketPC".

POS 40 large

All touch layouts with coding " Layout_40". (= Resolution 1024 und 1152).
Note:
The layout for this touch screen POS can be configured via button "Add.data" with additional parameters.


Layout Type

Field with firmly defined selection options

A layout type is linked to the touch layout in this field. Links have already have been established in the database for all stndard touch layouts. Do not make any changes here.

Note:
Please note that the values for defaults of the touch layout are defined mainly by the entry in field "Layout Type". The values for width, height, lines and columns only applies to touch layouts for which the entry "Non POS 30" has been selected in field "Layout Type".

The general layout for the touch pages of the following terminal screens is defined with the default in field "Layout Type". This setting has priority over the values in fields height, width, columns and rows.

Layout type

Description

Non POS 30

All touch layouts without coding "_30", "_30L" and "_30LH".

POS 30

All touch layouts with coding "_30" and "_30H" and _30FH". (30L = 35 keys, 30F = 54 keys)

POS 30 large

All touch layouts with coding "_30L" and "_30LH".

POS 30 Pocket

All touch layouts with coding "PocketPC".

POS 40 large

All touch layouts with coding " Layout_40". (= Resolution 1024 und 1152).
Note:
The layout for this touch screen POS can be configured via button "Add.data" with additional parameters.


Overwrite

Button activated: This touch layout can be overwritten.
Button deactivated: This touch layout cannot be overwritten.

Normally internal touch layouts should be stored in numbers between 50 and 99 and they should be protected against being overwritten.

 

The standard version is supplied with the following touch layouts:

 

No.

Layout name

1

Standard layout

2

Fast Food Layout

3

Big layout

4

PocketPC layout

5

PocketPC layout_H

6

Big layoutXA

7

Layout_40_1024

8

Layout_40_1152

10

Standard layout_30

11

Standard Layout_30L

12

Std layout_30XA

13

Std Layout_30LXA

14

Std layout_30XB

15

Std Layout_30LXB

20

Standard layout_30H

21

Standard Layout_30LH

22

Std layout_30HXA

23

Std Layout_30LHXA

24

Std layout_30HXB

25

Std Layout_30LHXB

 

During creation of all touch layouts the system checks whether a touch layout which has been marked as protected against overwriting can be overwritten. In such a case the first free unprotected touch layout nos. in sectors 6..9;16..19; 26.29 and 35..50 will be used.

If this is successful a message is stored in file "errlog". However, the general sequence is no longer applicable and therefore the aim should be to program all internal layout with numbers over 50.

If the numbers of the sector have all been assigned creation of the touch layouts will be discontinued.


Add.data (Button)

If the touch layout "Layout_40_1024" and/or "Layout_40_1152" is selected for program "TerminalT2_40_1024" and/or "TerminalT2_40_1152" button  "Add.data" allows for access to the follow-up parameters with which the layout of the touch screen POS can be configured in detail.


Base colour- dir.in bmp

Entry range permitted: alphanumeric, max. 20 pos.

The names of the colour for the layout of the touch screen POS can be entered in this field.

 

The following names are permitted:

 

Note:
If, for example, a valid name is entered in field Base colour button "Init fields" can then be depressed and specific standard values are entered in the fields of this program..

All values in the fields are cleared with button "Clear fields".


Autom.ASC-Keyb.switch

Button activated: Automatic call-up of the ASCII keyboard is deactivated for all key events.
Button deactivated: Key events with activated parameter "Autom. ASC-Keyb." are executed.

Note:
Key events in which the operator has to enter additional alphanumeric positions can be parametered in such a way that the ASCII keyboard is automatically shown on the screen. If this function is activated for certain keys on various touch pages automatic display of the ASCII keyboard can be deactivated with this parameter.

The parameter "Autom.ASC-Keyb." which activates this function can be found in program "Touch page" via button "Layout Prg.".


Statusbar - Date

Button activated:  The day’s date is shown on the terminal.
Button deactivated: The day’s date is not shown on the terminal.


Statusbar - Date chars.

Entry range permitted: numeric, 1 - 99999

Default = 10 pos.

A value can be entered in this field to define the number of characters which are to be reserved for display of the date.


Statusbar - Date align

Entry range permitted: numeric, 0 - 2

Enter a value in this field to define the alignment of the date in the display field.

 

The following is permitted:

 


Statusbar - Time chars.

Entry range permitted: numeric, 1 - 99999

Default = 5 pos.

A value can be entered in this field to define the number of characters which are to be reserved for display of time.


Statusbar - Time align

Entry range permitted: numeric, 0 - 2

Enter a value in this field to define the alignment of the time in the display.

 

The following are permitted:


Statusbar - Operator

Button activated: The name of the signed on operator is shown in the status display.
Button deactivated: No display of the name of the signed on operator.


Statusbar - Operator chars.

Entry range permitted: numeric, 1 - 99999

Default = 8 pos.

A value can be entered in this field to define the number of characters which are to be reserved for display of the operator name.


Statusbar - Operator align

Entry range permitted: numeric, 0 - 2

Enter a value in this field to define the alignment of the operator name in the display field.

 

The following are permitted:

 


Statusbar - TableNo.

Button activated: The number of the active table is shown in the status display.
Button deactivated:  No display of the table no. in the status line.


Statusbar - TableNo. chars.

Entry range permitted: numeric, 1 - 99999

Default = 5 pos.

A value can be entered in this field to define the number of characters which are to be reserved for display of the table no..


Statusbar - TableNo. align

Entry range permitted: numeric, 0 - 2

Enter a value in this field to define the alignment of the table no. in the display field.

 

The following are permitted:


Statusbar - Profit Center

Button activated: The no. of the profit center to which this terminal is linked is shown in the status display 
Button deactivated:  The no. of the linked profit center for this terminal is not shown.


Statusbar - Profit Center chars.

Entry range permitted: numeric, 1 - 99999

Default = 12 pos.

A value can be entered in this field to define the number of characters which are to be reserved for display of the profit center no.. 


Statusbar- Profit Center align

Entry range permitted: numeric, 0 - 2

Enter a value in this field to define the alignment of the profit center no. in the display.

 

The following are permitted:


Statusbar - Customer

Button activated:  The name of the current customer is shown in the status display of the terminal.
Button deactivated:  The customer’s name is not shown in the status display.


Statusbar - Customer chars.

Default = 9 pos.

A value can be entered in this field to define the number of characters which are to be reserved for display of the customer no.. 


Statusbar - Customer align

Entry range permitted: numeric, 0 - 2

Enter a value in this field to define the alignment of the customer name in the display field.

 

The following are permitted:


Statusbar - Terminal

Button activated: The terminal no. is displayed in the status display.
Button deactivated: No display of the terminal no. in the status display.


Statusbar - Terminal chars.

Default = 8 pos.

A value can be entered in this field to define the number of characters which are to be reserved for display of the terminal no..


Statusbar - Terminal align

Entry range permitted: numeric, 0 - 2

Enter a value in this field to define the alignment of the terminal no. in the display field.

 

The following are permitted:


NewDesign

Entry range permitted: numeric, 0 - 9

If the New Design 1 or 2 (see Touch layout) should be used for Sales application SalesT2 and SalesT3 with the touch layout Standard layout and Big Layout the following settings are necessary:

 

Additionally the value 4 (white) has to be set in Program System -> User interface -> in field Back color., to set the white background for the buttons.

 


Form Background Color

Entry range permitted: numeric, 0 - 9999

If the New Design 1 or 2(see Touch layout) should be used for Sales application SalesT2 and SalesT3 with the touch layout Standard layout and Big Layout the following settings are necessary:

 

Additionally the value 4 (white) has to be set in Program System -> User interface -> in field Back color., to set the white background for the buttons.

 


Normal Button Start Brush Color

Entry range permitted: numeric, 0 - 9999

If the New Design 1 or 2 (see Touch layout) should be used for Sales application SalesT2 and SalesT3 with the touch layout Standard layout and Big Layout the following settings are necessary:

 

Additionally the value 4 (white) has to be set in Program System -> User interface -> in field Back color., to set the white background for the buttons.

 


Normal Button End Brush Color

Entry range permitted: numeric, 0 - 9999

If the New Design 1 or 2 (see Touch layout) should be used for Sales application SalesT2 and SalesT3 with the touch layout Standard layout and Big Layout the following settings are necessary:

 

Additionally the value 4 (white) has to be set in Program System -> User interface -> in field Back color., to set the white background for the buttons.

 


Mark Button Start Brush Color

Entry range permitted: numeric, 0 - 9999

If the New Design 1 or 2 (see Touch layout) should be used for Sales application SalesT2 and SalesT3 with the touch layout Standard layout and Big Layout the following settings are necessary:

 

Additionally the value 4 (white) has to be set in Program System -> User interface -> in field Back color., to set the white background for the buttons.

 


Mark Button End Brush Color

Entry range permitted: numeric, 0 - 9999

If the New Design 1 or 2(see Touch layout) should be used for Sales application SalesT2 and SalesT3 with the touch layout Standard layout and Big Layout the following settings are necessary:

 

Additionally the value 4 (white) has to be set in Program System -> User interface -> in field Back color., to set the white background for the buttons.

 


Zoom receipt window

Button activated:  The spacing for the positions in the receipt window is doubled.
Button deactivated:  No double spacing in receipt window.


Is hospitality

Button activated:  Function keys are set for hospitality mode.
Button deactivated: Function keys are set for self-service mode (SS).


Rec.window backgr.col.

Entry range permitted: numeric, 1 - 9999

This parameter defines the colour in the background of the receipt window.

The colour is linked by entry of a col.no. and the name which can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


List Alt. Colour

This parameter is used to define the alternative background colour of recording positions in a receipt window, i.e. for a better overview individual recording items in the receipt window can be shown in different background colours.

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


Textline Font

Entry range permitted: numeric, 1 - 999

Default = font type = 30

A value can be entered in this field to define the font type for the textline (2nd line over the receipt window).


Textline Font size

Entry range permitted: numeric, 1 - 99999

Default = font size = 17

A value can be entered in this field to define the font size for the textline (2nd line above the receipt window).


Textline BgColour

Entry range permitted: numeric, 1 - 9999

This parameter defines the background colour for the textline (2nd line above the receipt window).

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


Textline FgColour

Entry range permitted: numeric, 1 - 9999

This parameter defines the foreground colour (font colour) for the textline (2nd line above the receipt window).

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


Boldline Font

Entry range permitted: numeric, 1 - 999

Default = font type = 36

The entry in this field defines the font type for the boldline (1st line above the receipt window).


Boldline Font size

Entry range permitted: numeric, 1 - 99999

Default = font size = 17

The entry in this field defines the font size for the boldline (1st line above the receipt window).


Boldline BgColour

The background colour of the bold line (1st line above the receipt window) is defined with this parameter.

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


Boldline FgColour

This parameter defines the foreground colour (font colour) of the boldline (1st line above the receipt window).

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


Echoline Font

Entry range permitted: numeric, 1 - 999

Default = font type = 36

The entry in this field defines the font type for the echoline (line above the key pad).


Echoline Font size

Entry range permitted: numeric, 1 - 99999

Default = font size = 17

The entry in this field defines the font size for the echoline (line above the key pad) .


Echoline BgColour

Entry range permitted: numeric, 1 - 9999

This parameter defines the background colour (font colour) of the echoline (line above the key pad).

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


Echoline FgColour

Entry range permitted: numeric, 1 - 9999

This parameter defines the foreground colour (font colour) of the echoline (line above the key pad).

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


NumPad Font

Entry range permitted: numeric, 1 - 999

Default = font type = 31

The entry in this field defines the font type for the descriptors of the number pad.


NumPad Font size

Entry range permitted: numeric, 1 - 99999

Default = font size = 26

The entry in this field defines the font size of the descriptors for the number pad.


ASC-Keys Font

Entry range permitted: numeric, 1 - 999

Default = font type = 31

The entry in this field defines the font type for the lettering on the ASCII NumPad.


ASC-Keys Font size

Entry range permitted: numeric, 1 - 99999

Default = font size = 16

The entry in this field defines the font size for the lettering on the ASCII NumPad.


fTP-Keys Font

Entry range permitted: numeric, 1 - 999

Default = font type = 31

Sie können in dieses Feld einen Wert eingeben, um den font type für die Beschriftung der FTP-Tasten auf der NumPad zu bestimmen.

 

Note:
FTP keys are keys with key events "FTP" linked to them to allow for change of page.


fTP-Keys Font size

Entry range permitted: numeric, 1 - 99999

Default = font size = 16

The entry in this field defines the font size for the lettering of the fTP keys on the NumPad.


Other keys Font

Entry range permitted: numeric, 1 - 999

Default = font type = 31

The entry in this field defines the font type for the lettering of other keys.


Other keys Font size

Entry range permitted: numeric, 1 - 99999

Default = font size = 13

The entry in this field defines the font size for the lettering of other keys.


DlgLblFont

Entry range permitted: numeric, 1 - 999

Default = font type = 31

The entry in this field defines the font type for the texts of the dialog window.


DlgBtnFont

Default = font type = 14

The entry in this field defines the font type for the keys of the dialog window.


DlgBgColour

Entry range permitted: numeric, 1 - 9999

This parameter defines the background colour of the dialog window.

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


Dlg FgColour

Entry range permitted: numeric, 1 - 9999

This parameter defines the foreground colour of the dialog window.

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


DlgBtn Colour

Entry range permitted: numeric, 1 - 9999

This parameter defines the button colour in the dialog window.

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


Dlg Border Colour

Entry range permitted: numeric, 1 - 9999

This parameter defines the border colour of the dialog window.

Link of the colour to the colour no. and the name can be found in the Colour table.

The right-hand button can be used to change to the window for update of the Colour. Colours can be mixed from entry of various colour shares (red, green, blue).


Browser Width

Entry range permitted: numeric, 1 - 9999

Default = 500 Pixel

The value entered in this field defines the width of the browser window (e.g. for help window "F1"or item information " INFOCHAR".).


Browser Height

Entry range permitted: numeric, 1 - 9999

Default = font type = 250 Pixel

The entry in this field defines the height of the browser window (e.g. for help window "F1"or item information " INFOCHAR".).


Index


MICROS Retail Deutschland GmbH
Salzufer 8