Go to main content
Netra SPARC S7-2 Server Installation Guide

Exit Print View

Updated: January 2017
 
 

Connect DC Power Source

  1. Connect the chassis ground wire to the facility ground, and ensure that the connections are properly tightened.

    See Connect the Chassis Ground Wire.

  2. Connect the -48V or -60V return and source wires to the circuit breaker or fuse panel, if they are not already connected.

    Caution

    Caution  -  Do not turn on the circuit breakers at this time.


  3. Connect a device to the SER MGT port.

    See Connect a Terminal or Emulator to the SER MGT Port.


    Note -  The server will enter Standby mode and the Oracle ILOM SP will initialize as soon as a power source is connected. System messages might be lost after 60 seconds if a terminal or terminal emulator is not connected to the SER MGT port before power is applied.

    Note -  Oracle ILOM will signal a fault if power is not applied to both supplies, because that is a nonredundant condition.

Related Information