Server Overview

The server is a carrier-grade, NEBS-certified, 2U server. This table summarizes the server's components. For detailed information about the server's features, go to http://www.oracle.com/goto/netra-s7-2.

Component
Description
Processor
Up to two SPARC 4.26 GHz CPUs (3.0 GHz in NEBS mode) with the following:
  • 4x integrated memory controllers per CPU

  • 8-cores and 64 threads per CPU

  • 2x Database Accelerator (DAX) per CPU

  • Integrated memory controller

Note -  The CPU configuration is set at the factory. A single CPU server cannot be upgraded to a dual CPU configuration.

Memory
The number of DDR4-2400MHz DIMM slots depends on the CPU configuration..
  • Single Processor – 8 slots that support 16-GB, 32-GB, or 64-GB capacities.

  • Dual Processor – 16 slots (8 slots per CPU) that support 16-GB, 32-GB, or 64-GB capacities.

Note -  The quantity and capacity of installed memory varies based on what was ordered.

Storage
  • Eight SFF slots for a maximum of eight SAS HDDs/SDDs

  • Four of the SFF slots can be used for NVMe SDDs

Service processor
On the motherboard, an internal SP with cryptographic acceleration that supports industry standard security ciphers. The SP runs Oracle ILOM firmware with provisions for:
  • Oracle ILOM 3.2.4

  • Serial management (RJ-45)

  • Network management (10/100/1000BASE-T Ethernet RJ-45)

Ethernet ports
Four 100/1000Mb/10Gb BASE-T Ethernet (RJ-45) with integrated link LEDs.
PCIe slots
Six PCIe x8 Gen3 slots. Two are usable as x16 Gen3 slots, however, the electrical max remains x8, up to 25 watts per card. All PCIe expansion slots support PCIe 3.0 / Gen3 (PCIe3) signaling levels.
PCIe internal HBA card
(Optional) One internal SAS HBA PCIe controller card.
USB ports
Two front 2.0 USB ports, and one rear 3.0 USB port.
eUSB flash drive
One internal eUSB drive.
Indicators and switches
  • Power button switch

  • Locate button switch with integrated LED

  • System OK LED

  • System Fault LED

  • Alarm LEDs - Critical (Red), Major (Red), Minor (Amber), User (Amber)

  • Rear PS fault LED

Power supplies
Depending on the model, one of the following configurations:
  • 2 hot-swappable AC supplies (Oracle model A266)

  • 2 hot-swappable DC supplies (Oracle model D258)

Note -  Mixing of AC and DC power supplies is not allowed.

Cooling
Front-to-back forced air, with high efficiency active fan speed control.

Related Information