Go to main content
oracle home
Netra SPARC S7-2 Server Service Manual
Exit Print View
Search Term
Search Scope:
This Document
Entire Library
» ...
Documentation Home
»
Netra SPARC S7-2 Server Documentation
»
Netra SPARC S7-2 Server Service Manual
Updated: February 2017
Netra SPARC S7-2 Server Service Manual
Document Information
Using This Documentation
Product Documentation Library
Feedback
Identifying Components
Component Locations (Storage, Power, NVMe, and Fan Modules)
Component Locations (Motherboard, Memory, and PCIe Cards)
Front Panel Components (Service)
Rear Panel Components (Service)
Customer-Replaceable Units
Related Information
Field-Replaceable Units
Related Information
Device Paths
Server Block Diagram (Dual Processor)
Detecting and Managing Faults
Checking for Faults
Log In to Oracle ILOM (Service)
Identify Faulted Components
Identify Disabled Components
Interpreting LEDs
Front Panel LEDs
Rear Panel LEDs
Performing Advanced Troubleshooting
Check the Message Buffer
View Log Files (Oracle Solaris)
View Log Files (Oracle ILOM)
POST Overview
Configure POST
Oracle ILOM Properties That Affect POST Behavior
Clear a Fault Manually
Server Fault Remind Button Operation
Preparing for Service
Safety Information
Safety Symbols
ESD Measures
Antistatic Wrist Strap Use
Antistatic Mat
Service Tools
Fillers
Find the Server Serial Number
Component Service Task Reference
Locate the Server
Removing Power From a Server
Prepare to Power Off a Server
Power Off the Server (Oracle ILOM)
Power Off the Server (Power Button - Graceful)
Power Off the Server (Emergency Shutdown)
Disconnect Power Cords and Data Cables
Accessing Internal Components
Prevent ESD Damage
Removing the Server From the Rack
Remove a Server From the 4-Post, 19-inch Rack
Remove the Cable Management Arm
Remove a Server From the 2-Post, 19-inch Rack
Remove the Top Cover
Remove the Fan Tray
Rotate the Drive Cage to the Service Position
Remove the PSU Duct
Remove the Air Duct
Servicing the Air Filter
Remove the Filter
Install the Filter
Servicing SAS Drives
SAS Drive Configuration
SAS Drive LEDs
Locate a Faulty Drive
Remove a SAS Drive
Install a SAS Drive
Verify a SAS Drive
Servicing NVMe Storage Drives
Unmount an NVMe Drive
Remove an NVMe Drive
Verify Removal of an NVMe Drive
Install an NVMe Drive
Power On an NVMe Drive and Attach a Device Driver
Verify the Operation of an NVMe Storage Drive
Servicing the eUSB Drive
Locate an eUSB Drive
Determine if an eUSB Drive is Faulty
Remove the eUSB Drive
Install the eUSB Drive
Servicing the USB Board
Remove the USB Board
Install the USB Board
Servicing the Drive Backplane
Drive Backplane Configuration
Determine if the Drive Backplane Is Faulty
Remove the Drive Backplane
Install the Drive Backplane
Verify the Drive Backplane
Servicing the DVD Drive
Remove the DVD Drive
Install the DVD Drive
Servicing Power Supplies
Power Supply LEDs
Locate a Faulty Power Supply
Remove a Power Supply
Install a Power Supply
Verify a Power Supply
Servicing the PDB
Determine if the PDB Is Faulty
Remove the PDB
Install the PDB
Verify the PDB
Servicing Fan Modules
Locate a Faulty Fan Module
Remove a Fan Module
Install a Fan Module
Verify a Fan Module
Servicing DIMMs
Understanding DIMM Layout and Population Rules
DIMM Layout
DIMM Population Rules
Locate a Faulty DIMM
Remove a DIMM
Install a DIMM
Verify a DIMM
Servicing PCIe Cards
PCIe Card Configurations
I/O Root Complex Connections
PCIe Device NAC Names
Locate a Faulty PCIe Card
Remove a PCIe Card
Install a PCIe Card
Verify a PCIe Card
Servicing the Internal HBA PCIe Card
Remove the Internal HBA PCIe Card
Install the Internal HBA PCIe Card
Verify the Internal HBA PCIe Card
Servicing the Battery
Remove the Battery
Install the Battery
Servicing the Cables
Cable Configurations
Servicing the SAS Drive Signal Cable
Remove the SAS Drive Signal Cable
Install the SAS Drive Signal Cable
Servicing the Drive Power Cable
Remove the Drive Power Cable
Install the Drive Power Cable
Servicing the PDB Signal Cable
Remove the PDB Signal Cable
Install the PDB Signal Cable
Servicing the NVMe Cables
Remove NVMe Cables
Install NVMe Cables
Servicing HBA SAS Cables
Remove HBA SAS Cables
Install HBA SAS Cables
Servicing the LED Board
Determine if the LED Board Is Faulty
Remove the LED Board and Cable
Install the LED Board and Cable
Verify the LED Board
Servicing the Motherboard
Determine if the Motherboard Is Faulty
Remove the Motherboard
Install the Motherboard
Verify the Motherboard
Returning a Server to Operation
Install the Air Duct
Install the PSU Duct
Secure the Drive Cage
Install the Fan Tray
Install the Top Cover
Connect AC Power Cords
Power On the Server (Oracle ILOM)
Power On the Server (Power Button)
Index
Index Numbers and Symbols
Index A
Index B
Index C
Index D
Index E
Index F
Index G
Index H
Index I
Index L
Index M
Index N
Index O
Index P
Index R
Index S
Index T
Index U
Index V
Index W
Language:
English
Netra SPARC S7-2 Server Service Manual
February 2017
Describes how to troubleshoot and maintain the Netra SPARC S7-2 server from Oracle.
Document Information
Using This Documentation
Product Documentation Library
Feedback
Identifying Components
Component Locations (Storage, Power, NVMe, and Fan Modules)
Component Locations (Motherboard, Memory, and PCIe Cards)
Front Panel Components (Service)
Rear Panel Components (Service)
Customer-Replaceable Units
Related Information
Field-Replaceable Units
Related Information
Device Paths
Server Block Diagram (Dual Processor)
Detecting and Managing Faults
Checking for Faults
Log In to Oracle ILOM (Service)
Identify Faulted Components
Identify Disabled Components
Interpreting LEDs
Front Panel LEDs
Rear Panel LEDs
Performing Advanced Troubleshooting
Check the Message Buffer
View Log Files (Oracle Solaris)
View Log Files (Oracle ILOM)
POST Overview
Configure POST
Oracle ILOM Properties That Affect POST Behavior
Clear a Fault Manually
Server Fault Remind Button Operation
Preparing for Service
Safety Information
Safety Symbols
ESD Measures
Antistatic Wrist Strap Use
Antistatic Mat
Service Tools
Fillers
Find the Server Serial Number
Component Service Task Reference
Locate the Server
Removing Power From a Server
Prepare to Power Off a Server
Power Off the Server (Oracle ILOM)
Power Off the Server (Power Button - Graceful)
Power Off the Server (Emergency Shutdown)
Disconnect Power Cords and Data Cables
Accessing Internal Components
Prevent ESD Damage
Removing the Server From the Rack
Remove a Server From the 4-Post, 19-inch Rack
Remove the Cable Management Arm
Remove a Server From the 2-Post, 19-inch Rack
Remove the Top Cover
Remove the Fan Tray
Rotate the Drive Cage to the Service Position
Remove the PSU Duct
Remove the Air Duct
Servicing the Air Filter
Remove the Filter
Install the Filter
Servicing SAS Drives
SAS Drive Configuration
SAS Drive LEDs
Locate a Faulty Drive
Remove a SAS Drive
Install a SAS Drive
Verify a SAS Drive
Servicing NVMe Storage Drives
Unmount an NVMe Drive
Remove an NVMe Drive
Verify Removal of an NVMe Drive
Install an NVMe Drive
Power On an NVMe Drive and Attach a Device Driver
Verify the Operation of an NVMe Storage Drive
Servicing the eUSB Drive
Locate an eUSB Drive
Determine if an eUSB Drive is Faulty
Remove the eUSB Drive
Install the eUSB Drive
Servicing the USB Board
Remove the USB Board
Install the USB Board
Servicing the Drive Backplane
Drive Backplane Configuration
Determine if the Drive Backplane Is Faulty
Remove the Drive Backplane
Install the Drive Backplane
Verify the Drive Backplane
Servicing the DVD Drive
Remove the DVD Drive
Install the DVD Drive
Servicing Power Supplies
Power Supply LEDs
Locate a Faulty Power Supply
Remove a Power Supply
Install a Power Supply
Verify a Power Supply
Servicing the PDB
Determine if the PDB Is Faulty
Remove the PDB
Install the PDB
Verify the PDB
Servicing Fan Modules
Locate a Faulty Fan Module
Remove a Fan Module
Install a Fan Module
Verify a Fan Module
Servicing DIMMs
Understanding DIMM Layout and Population Rules
DIMM Layout
DIMM Population Rules
Locate a Faulty DIMM
Remove a DIMM
Install a DIMM
Verify a DIMM
Servicing PCIe Cards
PCIe Card Configurations
I/O Root Complex Connections
PCIe Device NAC Names
Locate a Faulty PCIe Card
Remove a PCIe Card
Install a PCIe Card
Verify a PCIe Card
Servicing the Internal HBA PCIe Card
Remove the Internal HBA PCIe Card
Install the Internal HBA PCIe Card
Verify the Internal HBA PCIe Card
Servicing the Battery
Remove the Battery
Install the Battery
Servicing the Cables
Cable Configurations
Servicing the SAS Drive Signal Cable
Remove the SAS Drive Signal Cable
Install the SAS Drive Signal Cable
Servicing the Drive Power Cable
Remove the Drive Power Cable
Install the Drive Power Cable
Servicing the PDB Signal Cable
Remove the PDB Signal Cable
Install the PDB Signal Cable
Servicing the NVMe Cables
Remove NVMe Cables
Install NVMe Cables
Servicing HBA SAS Cables
Remove HBA SAS Cables
Install HBA SAS Cables
Servicing the LED Board
Determine if the LED Board Is Faulty
Remove the LED Board and Cable
Install the LED Board and Cable
Verify the LED Board
Servicing the Motherboard
Determine if the Motherboard Is Faulty
Remove the Motherboard
Install the Motherboard
Verify the Motherboard
Returning a Server to Operation
Install the Air Duct
Install the PSU Duct
Secure the Drive Cage
Install the Fan Tray
Install the Top Cover
Connect AC Power Cords
Power On the Server (Oracle ILOM)
Power On the Server (Power Button)
Index
Numbers and Symbols
A
B
C
D
E
F
G
H
I
L
M
N
O
P
R
S
T
U
V
W