Netra SPARC S7-2 Server Service Manual

Exit Print View

Updated: February 2017
 
 

Install the Top Cover

Perform this task when you have previously removed the top cover.

  1. If you previously removed the PSU and air ducts, raised the drive cage, or removed the fan tray, complete these prerequisites in this order.

    See:

  2. Position the top cover on the server, with the front edge of the top cover 0.5 in. (13 mm) rearward of the front edge of the server.
    image:The illustration shows installing the top cover.
  3. Slide the top cover forward into place.
  4. Secure the top cover with the two captive screws at the rear.
    image:The illustration shows tightening the screws.
  5. Install the server into the rack.

    Refer to the Netra SPARC S7-2 Server Installation Guide, installing the server into the rack.

  6. Connect the power cords.

    See Connect AC Power Cords.