Disconnect Power Cords and Data Cables

  1. When performing a cold-swap procedure, power off the server.

    See:

  2. Unplug all power cords from the server.

    Caution

    Caution  -  Because 12+ VDC standby power is always present in the system, you must unplug the power cords before accessing any cold-serviceable components.


    • For AC power cords.


      image:The illustration shows removing the AC power cord.
    • For DC power supply:

      • Turn off the main power circuit breaker to the server's power supply unit.


      • Caution

        Caution  -  Do not proceed with these instructions until you are sure that there is no voltage present on the DC cords and their power source.


      • Remove the terminal housing and the ring nuts, then the power cables followed last by the grounding wire.


    image:Illustration shows close-up view of DC power supply cords.
  3. Disconnect and remove all of the data cables that are attached to the rear of the server.

    See Servicing the Cables.