Go to main content
Netra SPARC S7-2 Server Service Manual

Exit Print View

Updated: February 2017
 
 

Verify the Internal HBA PCIe Card

After you install the internal HBA PCIe card, you can verify its functionality.

  1. Access Oracle ILOM.

    See Log In to Oracle ILOM (Service).

  2. Reset the card.
    -> set /SYS/MB/PCIE7 clear_fault_action=true
    Are you sure you want to clear /SYS/MB/PCIE1 (y/n)? y
    Set 'clear_fault_action' to 'true'
    
    ->
  3. Verify that the card is recognized.
    -> show /System/PCI_Devices/Add-on
     /System/PCI_Devices/Add-on
     	Targets:
     		Device_7
    ...
    ->

    If the card is not recognized, check its installation.

  4. Verify that the card is identified.
    -> show /System/PCI_Devices/Add-on/Device_7
  5. If the card is not recognized, try to locate it.

    See Locate a Faulty PCIe Card.

Related Information