Check to see if any Server Service Required LEDs are lit or flashing.
See Front Panel Components (Service) and Interpreting LEDs.
-
In Oracle ILOM, verify that the eUSB drive is recognized and check the fault_state.
->show/SYS/MB/EUSB_DISK/
./SYS/MB/EUSB_DISK
....Targets:
....Properties:
....type.=.Flash.Mini-Disk
....fault_state.=.OK
....clear_fault_action.=.none)
....Commands:
....cd
....set
....show
...
->
-
Use the Oracle ILOM faultmgmt shell or the fmadm faulty command to identify a faulty component.
See Identify Faulted Components.
Check the Fault class and Description fields for more information.
-
If an eUSB drive is faulty, replace it.
See Remove the eUSB Drive.
-
If you are unable to determine if an eUSB drive is faulty, seek further information.
See Detecting and Managing Faults.