Go to main content
Netra SPARC S7-2 Server Service Manual

Exit Print View

Updated: February 2017
 
 

Determine if an eUSB Drive is Faulty

  1. Check to see if any Server Service Required LEDs are lit or flashing.

    See Front Panel Components (Service) and Interpreting LEDs.

  2. In Oracle ILOM, verify that the eUSB drive is recognized and check the fault_state.
    ->show/SYS/MB/EUSB_DISK/
    ./SYS/MB/EUSB_DISK
    ....Targets:
    ....Properties:
    ....type.=.Flash.Mini-Disk
    ....fault_state.=.OK
    ....clear_fault_action.=.none)
    ....Commands:
    ....cd
    ....set
    ....show
    ...
    ->
  3. Use the Oracle ILOM faultmgmt shell or the fmadm faulty command to identify a faulty component.

    See Identify Faulted Components.

    Check the Fault class and Description fields for more information.

  4. If an eUSB drive is faulty, replace it.

    See Remove the eUSB Drive.

  5. If you are unable to determine if an eUSB drive is faulty, seek further information.

    See Detecting and Managing Faults.

Related Information