Electrical Specifications
The values in this table are for the power supplies. Use the online power calculator
to determine the power consumption of a server with your configuration: http://www.oracle.com/goto/powercalculators.
|
|
|
Voltage (nominal)
|
100-127 VAC (800W max out)
200 to 240 VAC (1200W max out)
|
-48/-60 VDC (1200W max out)
40-47 VDC (900W max out)
|
Input current (maximum)
|
10A (100-127 VAC)
7A (200-240 VAC)
|
36A max @ -48 VDC bus
28A max @ -60 VDC bus
|
Frequency (nominal)
|
50/60 Hz
|
0 Hz
|
Input treatment
|
N/A
|
Isolated DC Return (DC-I)
|
|
| Caution -
The ports of this equipment or subassembly are suitable for connection to
intra-building or unexposed wiring or cabling only. The intra-building port(s) of
the equipment or subassembly must not be metallically connected to interfaces that
connect to the outside plant wiring. These interfaces are designed for use as
intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE,
Issue 6) and require isolation from the exposed outside plant cabling. The addition
of primary protectors is not sufficient protection in order to connect these
interfaces metallically to outside plant wiring.
|
| Caution -
The intra-building port(s) of the equipment or subassembly must use
shielded intra-building cabling or wiring that is grounded at both ends, except the ethernet ports.
|
| Caution -
Mixing power supply types (AC and DC) is not allowed.
|