System chassis
|
1U chassis (Oracle Server X8-2)
2U chassis (Oracle Server X8-2L)
|
Processor
|
One or two processors with six integrated DDR4 memory controllers
per processor. Processors with the following capabilities are
supported (factory installed):
(Oracle Server X8-2)
-
Intel Xeon 8260, 24 core, 2.4 GHz, 165 W
-
Intel Xeon 5218, 16 core, 2.3 GHz, 125 W
-
Intel Xeon 5222, 4 core, 3.8 GHz, 105
W
(Oracle Server X8-2L)
-
Intel
Xeon 8268, 24 core, 2.9 GHz, 205 W
-
Intel Xeon 8260, 24 core, 2.4 GHz, 165
W
-
Intel Xeon 5218, 16 core, 2.3 GHz, 125 W
-
Intel Xeon 5222, 4 core, 3.8 GHz, 105
W
|
Memory
|
(Oracle Server X8-2)
-
Up to 12 16 GB DDR4-2666 registered DIMMs (single rank)
per processor
-
Up to 12 32 GB DDR4-2666 registered DIMMs per
processor
-
Up to 12 64 GB DDR4-2666 registered or TSV DIMMs per
processor
(Oracle Server X8-2L)
-
Up to 12 16 GB DDR4-2666 registered DIMMs (single rank)
per processor
-
Up to 12 32 GB DDR4-2666 registered DIMMs per
processor
-
Up to 12 64 GB DDR4-2666 registered or TSV DIMMs per
processor
|
Storage Drives (Oracle Server X8-2)
|
The storage drive configuration can comprise both hard disk drives
(HDDs) or solid state drives (SSDs). The configuration
includes:
-
Up to eight 2.5-inch hot-pluggable SAS3 HDDs or SATA3
SSDs, with optional support for up to eight 2.5-inch
NVM-Express (NVMe) SSDs
-
Two internal SATA/PCIe M.2 flash modules
|
Storage Drives (Oracle Server X8-2L)
|
The storage drive configuration can comprise both hard disk drives
(HDDs) or solid state drives (SSDs). The configuration
includes:
-
Up to twelve 3.5-inch hot-pluggable SAS3/SATA3 HDDs/SSDs,
or optional support for up to twelve 2.5-inch NVM-Express
(NVMe) SSDs
-
Two internal hot-pluggable SATA/PCIe M.2 flash
modules
Note -
The NVM-Express PCIe switch card is required for storage drive
configurations that contain NVMe SSDs.
|
PCI Express (PCIe) slots (Oracle Server X8-2)
|
Four PCIe Gen3 slots that accommodate low-profile PCIe
cards.
-
Slots 1 and 2: x16 electrical interface
-
Slot 3: x8 electrical interface
-
One additional internal x8 PCIe slot for use with an
optional internal host bus adapter (HBA) card. This internal
HBA card is used to control and manage the storage
drives.
Note -
PCIe slot 1 is nonfunctional in single-processor
systems.
|
PCI Express (PCIe) slots (Oracle Server X8-2L)
|
Eleven PCIe Gen3 slots that accommodate low-profile PCIe
cards.
-
Slots 1 and 7: x16 electrical interface
-
Slots 1 through 6, and slots 8 through 11: x8 electrical
interface
Note -
PCIe slots 1 through 5 are nonfunctional in single-processor
systems.
|
I/O ports (Oracle Server X8-2)
|
-
One RJ-45 serial management (SER MGT) Ethernet port
-
One 10/100/1000BASE-T RJ-45 Oracle Integrated Lights Out
Manager (ILOM) service processor (SP) network management
(NET MGT) Ethernet port
-
One 10/100/1000BASE-T RJ-45 Gigabit Ethernet (GbE) port,
labeled NET 0
-
Two 10/25GbE SFP+ Ethernet ports, labeled NET 1 and NET
2
-
Two 10GBASE-T RJ-45 Gigabit Ethernet (GbE) ports, labeled
NET 1 and NET 2
Note -
The 10/25GbE SFP+ Ethernet ports (NET 1 and NET 2) are the
default network ports for the server. When using an SFP+ port,
network connectivity is disabled on the 10GBASE-T RJ-45 GbE (NET
1 and NET 2) Ethernet ports.
|
I/O ports (Oracle Server X8-2L)
|
-
One RJ-45 serial management (SER MGT) Ethernet port
-
One 10/100/1000BASE-T RJ-45 Oracle Integrated Lights Out
Manager (ILOM) service processor (SP) network management
(NET MGT) Ethernet port
-
One 10/100/1000BASE-T RJ-45 Gigabit Ethernet (GbE) port,
labeled NET 0
|
USB 3.0 ports
|
One back panel, and one internal.
|
Service processor (SP)
|
The server has an integrated service processor (SP), features
include:
-
Oracle Integrated Lights Out Manager (ILOM)
Refer to the server product notes for Oracle ILOM release
information.
-
Local Oracle ILOM command-line access using a serial
connection
-
Support for Ethernet access to the SP through a dedicated
management port (NET MGT) and optionally through one of the
host Ethernet ports (sideband management)
-
IPMI 2.0-compliant remote management capabilities
-
Support for remote KVMS (keyboard, video, mouse, and
storage) over IP
|
Management software
|
|
Power supplies
|
Two hot-swappable and highly-redundant 1200W power
supplies.
|
Cooling fans (Oracle Server X8-2)
|
Four 40-mm, hot-swappable fan modules for chassis cooling. Each
fan module contains two counter-rotating fan pairs. Each power
supply has its own cooling fans.
|
Cooling fans (Oracle Server X8-2L)
|
Four 80-mm, hot-swappable fan modules for chassis cooling. Each
fan module contains one pair of counter-rotating fans. Each power
supply has its own cooling fans.
|
Operating systems and virtualization software
|
Refer to the server Product Notes for supported OS release
information.
|