Go to main content

Oracle® Servers X8-2 and X8-2L Installation Guide

Exit Print View

Updated: January 2021
 
 

Connect Cables and Power Cords

  1. For network access, connect an Ethernet cable between the server's Ethernet ports (NET0, NET1, or NET2) and the network to which the server will communicate.

    See Ethernet Ports.

  2. Connect any other cables to back panel accessible connections, as needed.
  3. Make a connection to the Oracle ILOM service processor.

    See Server Management Connection Options.

    Choose one of the following options:

    • Connect a serial cable the server's serial management port (SER MGT) and a terminal device.

      After initial configuration, you can connect and configure access using the Ethernet management (NET MGT) port.

    • Connect an RJ-45 Ethernet cable to the server's management port (NET MGT) and the management network.
  4. Connect two power cords to two power supplies at the back of the server from two separate AC power sources.

    Use Velcro straps to secure power cords to the power supply handles.

    The server is equipped with two power supplies. The server can operate with one power source; however, using only one power source eliminates redundancy.

    Oracle Server X8-2:


    image:Figure showing the Oracle Server X8-2 AC power                             connections.

    Oracle Server X8-2L


    image:Figure showing Oracle Server X8-2L AC power connections.

    Caution  -  Damage to Server Components: Do not operate the server unless all included fans and components are fully installed.


  5. Confirm that the server is in Standby power mode.

    When the server power cords are connected, the following actions occur:

    • The green AC OK power supply indicators (LEDs) light.

    • The Oracle ILOM SP initializes. During initialization, the green SP OK LED flashes rapidly.

    • Once the Oracle ILOM SP has fully initialized, the green SP OK LED is steady on and the green System OK LED flashes slowly, indicating that the host is in Standby power mode.

    In Standby power mode, the server is not initialized or powered on.

Related Information