Fan Events
The following table lists fan events.
|
|
SNMP Trap:
sunHwTrapFanSpeedCritThresholdExceeded
Oracle ILOM Event Message:
Lower critical threshold exceeded
Severity and Description:
Major; A fan speed sensor has reported that its value has gone above
an upper critical threshold setting or below a lower critical
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-x]/TACH
|
SNMP Trap:
sunHwTrapFanSpeedCritThresholdDeasserted
Oracle ILOM Event Message:
Lower critical threshold no longer exceeded
Severity and Description:
Informational; A fan speed sensor has reported that its
value has gone below an upper critical threshold setting or above a
lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-x]/TACH
|
SNMP Trap:
sunHwTrapFanSpeedFatalThresholdExceeded
Oracle ILOM Event Message:
Lower fatal threshold exceeded
Severity and Description:
Critical; A fan speed sensor has reported that its value has gone
above an upper fatal threshold setting or below a lower fatal
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-x]/TACH
|
SNMP Trap:
sunHwTrapFanSpeedFatalThresholdDeasserted
Oracle ILOM Event Message:
Lower fatal threshold no longer exceeded
Severity and Description:
Informational; A fan speed sensor has reported that its value has
gone below an upper fatal threshold setting or above a lower fatal
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-x]/TACH
|
|