Go to main content

StorageTek Dual 8Gb FC Dual GbE HBA, ExpressModule, Emulex Installation Guide For HBA Models SG-XPCIEFCGBE-E8-Z, SG-PCIEFCGBE-E8-Z, SG-XPCIEFCGBE-E8-N, SG-PCIEFCGBE-E8-N and 7105393

Exit Print View

Updated: August 2018
 
 

To Verify Attached Storage (Oracle Solaris)

  1. Use the cfgadm -al command to verify attached storage.
    cfgadm -al
    

    If the HBA is properly installed and storage is connected properly, you will see output similar to the following example. In this example, one port of an HBA is connected through a fabric switch to two ports of a disk array.

            Ap_Id                  Type         Receptacle   Occupant     Condition
            c1                     fc-fabric    connected    configured   unknown
            c1::200600a0b816005e   disk         connected    configured   unknown
            c1::200700a0b816005e   disk         connected    configured   unknown
            c2                     fc           connected    unconfigured unknown
            pcie1                  pci-pci/hp   connected    configured   ok
    
  2. If an HBA is shown as unconfigured, use the cfgadm -c configure command to configure it.
  3. To view more information about the HBA, use the fcinfo hba-port command.