Go to main content

Sun Server X3-2 (formerly Sun Fire X4170 M3) Product Notes

Exit Print View

Updated: August 2019
 
 

MegaRAID Storage Manager not able to assign hot spares to 3-TB drives using EFI partitioning with the Sun Storage 6 Gb SAS PCIe HBA (15787798, formerly CR 7164218)

MegaRAID Storage Manager V11.08.03.02 is not able to assign hot spares if the virtual drive is based on the Sun Storage 6 Gb SAS PCIe HBA, Internal option card, and is constructed on 3-terabyte (3-TB) drives using Extensible Firmware Interface (EFI) partitioning.

Affected hardware and software:

  • Sun Storage 6 Gb SAS PCIe RAID HBA, Internal (SGX-SAS6-INT-Z and SG-SAS6-INT-Z)

  • MegaRAID Storage Manager V11.08.03.02

  • Releases 1.0 and later

Workaround:

Use the sas2ircu Utility until the defect in MegaRAID Storage Manager is corrected.