Determine Which DIMM Is Faulty (DIMM Fault LEDs)

DIMMs are cold-service components that can be replaced by customers. For the location of the DIMMs, see Processor Module Components.


Caution

Caution  -  This procedure requires that you handle components that are sensitive to electrostatic discharge. This discharge can cause failure of server components.


  1. Consider your first steps.
  2. Locate the DIMM Fault Remind button on the processor module.
    image:Illustration showing the location of the DIMM Fault                                 button
  3. Verify that the Memory Riser Power LED next to the button is illuminated.

    An illuminated Memory Riser Power LED indicates that there is power available to illuminate any Memory DIMM Fault LEDs once you have pressed the DIMM Fault Remind button.

  4. Press the DIMM Fault Remind button on the processor module.

    This will cause the Memory DIMM Fault LEDs associated with any faulty DIMMs to illuminate for a few minutes.

  5. Note the address of the DIMM next to any illuminated Memory DIMM Fault LED.
  6. Ensure that all other DIMMs are seated correctly in their slots.