Go to main content

SPARC T8-1 Server Installation Guide

Exit Print View

Updated: June 2019
 
 

Environmental Specifications

This topic includes these specifications that apply to both server configurations:

  • Temperature, humidity, and elevation

  • Shock and vibration

  • Acoustic

Table 1  Temperature, Humidity, and Elevation Specifications
Description
Operating
Nonoperating
Notes
U.S.
Metric
U.S.
Metric
Temperature (maximum)
41 to 95°F at 0 to 3000 ft
5 to 35°C at 900m
-40 to 149°F at 0 to 3000 ft
-40 to 65°C at 900m
Decrease in maximum temperature: above 3000 ft. (900m), 1.8°F/1000 ft (1°C/300m)
Relative humidity
10 to 80% at 81°F
10 to 80% at 27°C
Up to 85% at 100°F
Up to 85% at 38°C
Maximum wet bulb noncondensing
Altitude
0 to 9840 ft
at 95°F

Except in China markets where regulations might limit installations to a maximum altitude of 2km.

0 m to 3000m at 40°C
Up to 39,370 ft
Up to 12,000m
Table 2  Shock and Vibration Specifications
Description
Operating
Notes
Shock
3G, 11 ms
Half-sine
Vibration (vertical)
0.15G
5 to 500 HZ swept-sine
Vibration (horizontal)
0.10G
Table 3  Acoustic Specifications
Description
Operating at 60%
Operating at 100%
Sound Power Level - LwAd (1 B=10 dB)
8.2 B
9.7 B
Sound Pressure Level - LpAm (energy average of four bystander positions)
66.2 dBA
80.3 dBA

Related Information