Go to main content

SPARC T8-1 Server Installation Guide

Exit Print View

Updated: June 2019
 
 

Electrical Specifications

Description
Value
Notes
Voltage
200 to 240 VAC
Frequency
50 to 60 Hz
Maximum operating input current at 200 VAC (per cord)

The maximum operating input current values are based on P / (V *0.90), where P = max. operating input power, V= input voltage. Example: 620W / (120 * 0.90) = 6.89A You can use this equation to calculate your maximum operating current at your input voltage.

5.7 A
Actual amperage draw may exceed rating by no more than 10%.
Maximum operating input power at 200 VAC
1300W
Maximum standby power
20W
Maximum heat dissipation
4456 BTU/hr
4702 KJ/hr

For information on power specifications, use the power calculator at:

http://www.oracle.com/us/products/servers-storage/sun-power-calculators

Related Information