This topic includes these specifications:

  • Temperature, humidity, and elevation

  • Shock and vibration

  • Acoustic

Table 1  Temperature, Humidity, and Elevation Specifications
Operating
Nonoperating
Description
U.S.
Metric
U.S.
Metric
Notes
Temperature (maximum)
41 to 95??F at 0 to 3000 ft
5 to 35??C
at 900m
-40 to 149??F
at 0 to 3000 ft
-40 to 65??C
at 900m
Decrease in maximum temperature: above 3000 ft. (900m), 1.8°F/1000 ft (1°C/300m)
Relative humidity
10 to 90%
at 81??F
10 to 90%
at 27??C
Up to 93%
at 100??F
Up to 93%
at 38??C
Maximum wet bulb, noncondensing
Altitude
0 to 9840 ft at 95°F

Except in China markets where regulations may limit installations to a maximum altitude of 2km.

0 to 3000m
at 40??C
Up to 40,000 ft
Up to 12,000m
Table 2  Shock and Vibration Specifications
Description
Operating
Notes
Shock
3G, 11 ms
Half-sine
Vibration (vertical)
0.15G
5 to 500 HZ swept-sine
Vibration (horizontal)
0.10G
Table 3  Acoustic Specifications
Description
Operating at Idle
Operating at Peak Power
Acoustic power (LwAd 1B= 10 dB)
7.8B
9.4B
Acoustic pressure level (LpAm: bystander positions)
61.8 dBA
79.7 dBA