Sun Server X4-8 Service Manual

Exit Print View

Updated: March 2018
 
 

Component Designations

These sections show the location and designation of CRU and FRU components:

Fan Module Designations

The eight fan modules (FMs) are directly accessible at the front of the server and are arranged in two stacked rows of four FMs. The bottom row of four fan modules are designated from left to right as, FM 0, FM 2, FM 4, and FM 6. The top row of four fan modules are designated from left to right as, FM 1, FM 3, FM 5, and FM 7.

image:An illustration with call outs showing the Fan Module                             designations.
Call Out
Description
0
FM 0
1
FM 1
2
FM 2
3
FM 3
4
FM 4
5
FM 5
6
FM 6
7
FM 7

The eight fan modules are contained in two separate side by side enclosures (frames). Each frame contains four FMs (two stacked rows of two FMs). The left side frame contains FM 0, FM1, FM2, and FM 3. The right-side frame contains FM 4, FM 5, FM 6, and FM 7.

Additionally, the FMs and frames have a relationship to the CPU modules (CMODs), which are installed directly behind the FMs (and for which the FMs provide cooling). The left-side frame contains the FMs (0–3) that provide cooling for CMODs 0–3, and the right-side frame contains the FMs (4–7) that provide cooling for CMODs 4–7 . For CMOD designations, see CMOD Slot Designations.

Power Supply Slot Designations

The four slots for the power supply units (PSUs) are directly accessible at the front of the server and are arranged in a single stacked row and designated from the bottom to the top as, PSU 0, PSU 1, PSU 2, and PSU 3. The following illustration shows the arrangement of the PSUs.

image:An illustration with call outs showing the power supply                             designations.
Call Out
Description
0
PSU 0
1
PSU 1
2
PSU 2
3
PSU 3

CMOD Slot Designations

The server is available in two CPU module (CMOD) configurations: four CMODs or eight CMODs (for more information, see CPU Module (CMOD) Overview). The slots for the CMODs are accessible from the front of the server by removing the FM frames. The slots are arranged in a single row and are designated from left to right as, CMOD 0–CMOD 7.

image:An illustration with call outs showing the CMOD                             designations.
Call Out
Description
0
CMOD 0
1
CMOD 1
2
CMOD 2
3
CMOD 3
4
CMOD 4
5
CMOD 5
6
CMOD 6
7
CMOD 7

Memory Slot Designations

Memory is installed on the CPU modules (CMODs). Each CMOD contains 24 DIMM slots. The slots are arranged in four groups of six slots. The following illustration shows the arrangement of the four groups on the CMOD and shows the designation of each slot.

image:An illustration with call outs showing the DIMM slot                             designations.
Call Out
Description
1
Slots D12–D17
2
Slots D18–D23
3
Slots D6–D11
4
Slots D0–D5

Storage Drive Slot Designations

The eight storage drive slots are in the system module (SMOD) and directly accessible at the back of the server. Slots are arranged in two stacked rows of four slots and designated from right to left. The four slots in the bottom row are designated as slots 0, 2, 4, and 6. The four slots in the top row are designated as, 1, 3, 5, and 7.

image:An illustration with call outs showing the storage drive slot                             designations.
Call Out
Description
0
Slot 0
1
Slot 1
2
Slot 2
3
Slot 3
4
Slot 4
5
Slot 5
6
Slot 6
7
Slot 7

DPCC and PCIe Card Slot Designations

The eight dual PCIe card carrier (DPCC) slots are directly accessible at the back of the server and are arranged in a single row. The slots are designated from right to left as, DPCC 0–DPCC 7. Additionally, the 16 PCIe cards slots are also designated from right to left as PCIe 1–PCIe 16. Each DPCC contains two PCIe card slots as shown below:

  • DPCC 0 contains PCIe slots 1 and 2

  • DPCC 1 contains PCIe slots 3 and 4

  • DPCC 2 contains PCIe slots 5 and 6

  • DPCC 3 contains PCIe slots 7 and 8

  • DPCC 4 contains PCIe slots 9 and 10

  • DPCC 5 contains PCIe slots 11 and 12

  • DPCC 6 contains PCIe slots 13 and 14

  • DPCC 7 contains PCIe slots 15 and 16

The following illustration shows the location and designations of the PCIe slots.

image:Picture with callouts for PCIe slots.
Call Out
Description
Call Out
Description
1
PCIe Slot 1 in DPCC 0
9
PCIe PCIe Slot 9 in DPCC 4
2
PCIe Slot 2 in DPCC 0
10
PCIe Slot 10 in DPCC 4
3
PCIe Slot 3 in DPCC 1
11
PCIe Slot 11 in DPCC 5
4
PCIe Slot 4 in DPCC 1
12
PCIe Slot 12 in DPCC 5
5
PCIe Slot 5 in DPCC 2
13
PCIe Slot 13 in DPCC 6
6
PCIe Slot 6 in DPCC 2
14
PCIe Slot 14 in DPCC 6
7
PCIe Slot 7 in DPCC 3
15
PCIe Slot 15 in DPCC 7
8
PCIe Slot 8 in DPCC 3
16
PCIe Slot 16 in DPCC 7

AC Input Power Block

The four AC power inputs are accessible at the back of the server and are arranged in a single stacked row. The inputs are designated from bottom to top (corresponding to the PSUs on the front side) as, (bottommost) AC 0, AC 1, AC 2, and AC 3. The AC power block is not a removable component.

The following illustration shows the location and designation of the inlets on the AC power block.

image:An illustration with call outs showing the AC inlet                             designations.
Call Out
Description
0
AC 0
1
AC 1
2
AC 2
3
AC 3