Documentation, Support, and Training
Understanding ILOM on the Switch
Administering ILOM (Web Interface)
Understanding Switch-Specific Commands
activate Command (switch-specific)
deactivate Command (switch-specific)
Sets component to debug. Issued on the CMC.
selectdebugport lc|fc slot
where slot is number of the line card (0–8) or fabric card (0–8).
This switch-specific command enables you to directly communicate with the H8 chip of the specified line card or fabric card, circumventing the indirect control of the CMC software. The selectdebugport command sets which line card or fabric card is addressed through the debug port of the CMC. The debug port is located between the NET MGT and SER MGT connectors, and uses the serial communication parameters of 9600, 8, N, 1, and no flow control.
Note - Resetting a CMC or performing a CMC switchover resets the debug port.
The following example shows how to set line card 8 for debugging through the debug port on the CMC with the setdebugport command.
# selectdebugport lc 8 #