Documentation, Support, and Training
Understanding ILOM on the Switch
Administering ILOM (Web Interface)
Understanding Switch-Specific Commands
activate Command (switch-specific)
deactivate Command (switch-specific)
Enables hot insertion of a card. Issued on the CMC.
enablehotinsert lc|fc slot
where slot is the number of the line card (0–8) or fabric card (0–8).
This switch-specific command readies the IPMB bus and standby power for a line card or fabric card slot before insertion, so that the bus and power are automatically enabled upon line card or fabric card insertion into that slot. This command is similar to the enableboard command or the enableipmb and enablestby commands, but is executed before the card is inserted.
The following example shows how to ready line card slot 8 for hot-insertion with the enablehotinsert command.
# enablehotinsert lc 8 lc 8 is now enabled #