Document Information
Using This Documentation
Product Notes
Related Documentation
Feedback
Access to Oracle Support
Installation
Understanding the Server
Installation Task Overview
Server Overview
System Status LEDs
Front Components
Rear Components
Understanding the Hardware Architecture
Understanding the Firmware and Software Environment
Preparing the Site
Site Preparation Checklist
General Installation Site Guidelines
Reviewing the Physical Specifications
Reviewing the Power Requirements
Preparing for Cooling
Preparing the Unloading Route and Unpacking Area
Planning Network Addresses
Preparing for Installation
Handling Precautions
ESD Precautions
Oracle Safety Information
Equipment Needed for Installation
Attach an Antistatic Wrist Strap
Installing the Server
Confirm the Site Preparation
Receive the Server
Unpack the Server
Moving the Server
Stabilizing the Server
Optional Component Installation
Connecting the Front SP Cables
Connect the SP Cables
Securing the SP Cables
Connecting the Rear Power Cords and Data Cables
Rear Cable Routing Options
Maximum Cable Connections
Cable Management Devices
Prepare the Cable Routing Brackets
Connect the Power Cords
Secure the Power Cords
Connect the EMS Network Cables
Connect Other Data Cables
Managing Data Cables
Powering On the Server for the First Time
Installed Software
Inspect the Power Cords
Dual-Redundant SPs
Connect Terminals or Emulators to the SP SER MGT Ports
Switch On the Facility Circuit Breakers
Log In to the Active SP
Set Oracle ILOM Network Addresses
Set the Altitude of the Server
Power On the Server
Oracle Solaris OS Configuration Parameters
Additional Software Configuration and Testing
Administration
Understanding the System Architecture
Architectural Overview
PDomain Types
Understanding PCIe Device Root Complexes
Control Domain and Reserved Root Complexes
PCIe Communication and Paths
Fully-Populated Default Configuration
Half-Populated Configuration
Understanding PCIe Slot Root Complex Names and Device Paths
Understanding DCU0 Root Complex Names and Device Paths
Understanding DCU1 Root Complex Names and Device Paths
Understanding DCU2 Root Complexes and Device Paths
Understanding DCU3 Root Complexes and Device Paths
PCIe Device Root Complex Failover Behavior
Understanding EMS SAS Paths to the Internal Drives
Drive Access With EMS SAS
EMS and HDD Numbering
SAS Paths From EMS Module to Drives
SAS Pathing Examples
Understanding Internal Drive Device Paths
HDD and SSD Device Path Differences
Understanding DCU0 Drive Device Paths
Fully-Populated DCU0 Drive Device Paths
Half-Populated DCU0 Hard Drive Device Paths
Understanding DCU1 Drive Device Paths
Fully-Populated DCU1 Drive Device Paths
Half-Populated DCU1 Drive Device Paths
Understanding DCU2 Drive Device Paths
Fully-Populated DCU2 Drive Device Paths
Half-Populated DCU2 Drive Device Paths
Understanding DCU3 Drive Device Paths
Fully-Populated DCU3 Drive Device Paths
Half-Populated DCU3 Drive Device Paths
Understanding Network Port Device Paths
Network Port Numbering
DCU0 Network Port Device Paths
DCU1 Network Port Device Paths
DCU2 Network Port Device Paths
DCU3 Network Port Device Paths
Understanding Configuration Guidelines
SP and SPP Guidelines
PDomain Guidelines
DCU, CMU, and CMP Guidelines
CMU Configuration Examples
Memory (DIMM) Guidelines
Understanding System Administration Resources
Oracle ILOM Overview
Understanding Platform-Specific Oracle ILOM Features
Oracle Solaris OS Overview
OpenBoot Overview
Oracle VM Server for SPARC Overview
Multipathing Software Overview
Oracle ILOM Remote System Console Plus Overview
Oracle Hardware Management Pack Overview
Oracle Enterprise Manager Ops Center
Time Synchronization and NTP Service
SNMP Service
Multi-Domain Extensions to ILOM MIBs
Active Directory
LDAP/SSL
Accessing the Server
Establish a Network Management Connection to Oracle ILOM
Logging In to Oracle ILOM
Log Out of Oracle ILOM
Switch Between the Oracle ILOM CLI and the System Console on a Host
Accessing the ok Prompt
Redirecting KVMS Devices
Controlling the Server, Domains, and Devices
Controlling the Power State
Resetting the Server, SP, or Domains
Managing the Server's Boot Behavior
Booting and Shutting Down the OS
Configuring Oracle ILOM User Accounts and Roles
Managing User Accounts
Managing User Authentication
Configuring the SP Network
Network Resources Overview
Record Network Parameter Values
Configure SP Network Settings
Viewing the Network Configuration
Administering SPs
Managing IP Addresses
Display the MAC Address
Configuring Domain Components
Configuring Physical Domains
Administering DCUs
Administering CMUs, CMPs, and DIMMs
Administering IOUs and PCIe Device Root Complexes
Identifying Domain-Level Commands
Monitoring the Server
Locating the Server
Obtain the Server Serial Number
Viewing Server and Component Information
Monitoring Faults
Updating the Firmware
Display the Firmware Version
Firmware Update Overview
Update the Firmware
XSCF and Oracle ILOM Command Comparison
Identifying SP Configuration and Administration Commands
Identifying Domain Administration Commands
Service
Identifying Components
Identifying Front Components
Identifying Rear Components
Side Panels
Identifying Internal Components
Understanding Scalability
Understanding Cooling Zones
Component Service Task Reference
Detecting and Managing Faults
Diagnostic Overview
Managing Faults
Interpreting Log Files and System Messages
Configuring POST
Interpreting LEDs
Preparing for Service
Service Sequence
Safety Information
Tools for Service
Torque Reference
Filler Panels
Find the Server Serial Number
Locate the Component
Power Off a PDomain
Removing Power From the Server
Servicing Cabinet Doors
Remove the Door
Install the Door
Servicing Side Panels
Remove Side Panels
Install Side Panels
Servicing Trim Panels and the Kick Plate
Trim Panel Service Preparation
Remove the Trim Panels
Install Trim Panels
Remove the Kick Plate
Install the Kick Plate
Servicing Power Supplies
Power Supply Configuration
Power Supply LEDs
Remove a Power Supply
Install a Power Supply
Servicing PSDBs
PSDB LEDs
Remove a PSDB
Install a PSDB
Servicing Fan Modules
Fan Module Configuration
Fan Module LEDs
Remove a Fan Module
Install a Fan Module
Servicing SSBs
SSB Configuration
SSB LEDs
Remove an SSB
Install an SSB
Servicing Clock Boards
Clock Board Configuration
Clock Board LEDs
Display the Clock Board Type
Remove a Clock Board
Install a Clock Board
Servicing Service Processors
Service Processor LEDs
Check a Service Processor Battery
Remove a Service Processor
Replace a Service Processor Battery
Install a Service Processor
Servicing I/O Switch Boards
I/O Switch Board Configuration
I/O Switch Board LEDs
Remove an I/O Switch Board
Install an I/O Switch Board
Servicing Cable Management Assemblies
Remove a Cable Management Assembly
Install a Cable Management Assembly
Servicing I/O Cards
Understanding I/O Card Slot Configuration
Understanding I/O Card Slot Device Paths and FRU Paths
Sun Flash Accelerator F40 and F80 PCIe Cards
PCIe Hot-Plug Carrier LEDs
Locate an I/O Card in the Server
Locate a Faulty I/O Card
Prepare an I/O Card For Removal
Remove an I/O Card From the Server
Remove an I/O Card From a Carrier
Install an I/O Card in a Carrier
Install an I/O Card in the Server
Remove a Filler Panel From the Server
Remove a Filler Panel From a Carrier
Install a Filler Panel in a Carrier
Install a Filler Panel in the Server
Verify an I/O Card
Relocate a Sun Flash Accelerator F40 PCIe Card
Servicing EMSs
Understanding EMS Configurations
EMS General Status LEDs
EMS Network Port LEDs
Determine Hard Drive Cage and EMS Part Numbers
Remove an EMS
Install an EMS
Servicing HDDs, SSDs, and Drive Filler Panels
Understanding HDD and SSD Slot Configurations
HDD LEDs
SSD LEDs
Locate a Drive
Removing an HDD
Install an HDD
Removing an SSD
Install an SSD
Remove a Drive Filler Panel
Install a Drive Filler Panel
Servicing SPPs
SPP Configuration
SPP LEDs
Check an SPP Battery
Remove an SPP
Replace an SPP Battery
Install an SPP
Servicing CMUs
CMU Configuration
CMU Upgrades in a SPARC M5-32 Server
CMU LEDs
Display General CMU Information
Display the CMU Quantity and Type
Unpacking and Inspecting a CMU
Remove a CMU
Install a CMU
Repack a CMU for Shipping
Remove a CMU Filler Panel
Install a CMU Filler Panel
Servicing DIMMs
Memory Configuration
DIMM FRU Names
Locate a Faulty DIMM
DIMM Fault Remind Button
Remove a DIMM
Install a DIMM
Move DIMMs to a New CMU
Servicing the Front LED Panel
Front LED Panel LEDs
Remove the Front LED Panel
Install the Front LED Panel
Servicing the Front Filler Panel
Remove the Front Filler Panel
Install the Front Filler Panel
Servicing Fan Cages
Fan Cage Configuration
Remove the Upper Fan Cage
Install the Upper Fan Cage
Remove the Lower Fan Cage
Install the Lower Fan Cage
Servicing a Cabled Lower Bus Bar Assembly
Remove a Cabled Lower Bus Bar Assembly
Install a Cabled Lower Bus Bar Assembly
Servicing the Scalability Card Cage
Remove the Scalability Card Cage
Install the Scalability Card Cage
Servicing the Scalability Fans Cable
Remove the Scalability Fans Cable
Install the Scalability Fans Cable
Servicing the Power System Cage
Remove the Power System Cage
Install the Power System Cage
Servicing Bus Bars
Bus Bar Configuration
Prepare to Replace Crown Clips on a Bus Bar
Replace Crown Clips
Return the Server to Operation
Servicing AC Power Cords
AC Power Cord Configuration
Remove an AC Power Cord
Install an AC Power Cord
Servicing AC Input Filters
AC Input Filter Configuration
Remove an AC Input Filter
Install an AC Input Filter
Disconnect AC Input Filters
Reconnect AC Input Filters
Servicing the Rear LED Panel
Rear LED Panel LEDs
Remove the Rear LED Panel
Install the Rear LED Panel
Servicing IOUs
Remove an IOU
Install an IOU
Servicing an I/O Power Cable Assembly
Remove an I/O Power Cable Assembly
Install an I/O Power Cable Assembly
Servicing Hard Drive Cages
Hard Drive Cage Configuration
Remove a Hard Drive Cage
Install a Hard Drive Cage
Servicing the Scalability Assembly
Remove the Scalability Assembly
Install the Scalability Assembly
Servicing the Fan Power Cable
Remove the Fan Power Cable
Install the Fan Power Cable
Servicing the Power System Cage to Scalability Assembly Cable
Remove the Power System Cage to Scalability Assembly Cable
Install the Power System Cage to Scalability Assembly Cable
Servicing the PSDB to Scalability Midplane Cable
Remove the PSDB to Scalability Midplane Cable
Install the PSDB to Scalability Midplane Cable
Servicing the Internal Link to Front LED Panel Cable
Remove the Internal Link Cable for the Front LED Panel
Install the Internal Link Cable for the Front LED Panel
Servicing the Rear LED Panel Cable
Remove the Rear LED Panel Cable
Install the Rear LED Panel Cable
Servicing Midplane Power Cables
Prepare to Remove a Midplane Power Cable
Remove a Midplane Power Cable
Install a Midplane Power Cable
Servicing the I/O Data Cable Assembly
Remove an I/O Data Cable Assembly
Install an I/O Data Cable Assembly
Servicing the Midplane
Inspect the Replacement Kit
Prepare to Remove the Midplane
Remove the Midplane
Install the Midplane
Reassemble the Server
Prepare the Old Midplane for Return
Returning the Server to Operation
Return to Operation Sequence
Reconnect AC Power to the Server
Restart the Server
Reset the Server
Reset Service Processors
Reset a PDomain
Restart a PDomain
Return a Component to Oracle
Glossary
Index
Fully-Populated DCU0 PCIe Slot Root Complexes
In a fully-populated default configuration, the PCIe I/O fabric paths from each root
complex to the PCIe and EMS slots in a fully-populated DCU0.
This table lists information for each PCIe and EMS slot in a fully-populated
DCU0.
|
|
|
|
|
PCIe 1 |
pci_11 |
CMU1/CMP1 |
/pci@5c0/pci@1/pci@0/pci@8 |
/SYS/IOU0/PCIE1 |
PCIe 2 |
pci_1 |
CMU0/CMP0 |
/pci@340/pci@1/pci@0/pci@2 |
/SYS/IOU0/PCIE2 |
PCIe 3 |
pci_0 |
CMU0/CMP0 |
/pci@300/pci@1/pci@0/pci@6 |
/SYS/IOU0/PCIe3 |
PCIe 4 |
pci_10 |
CMU1/CMP1 |
/pci@580/pci@1/pci@0/pci@4 |
/SYS/IOU0/PCIE4 |
PCIe 5 |
pci_2 |
CMU0/CMP1 |
/pci@380/pci@1/pci@0/pci@8 |
/SYS/IOU0/PCIE5 |
PCIe 6 |
pci_8 |
CMU1/CMP0 |
/pci@500/pci@1/pci@0/pci@2 |
/SYS/IOU0/PCIE6 |
PCIe
7 |
pci_9 |
CMU1/CMP0 |
/pci@540/pci@1/pci@0/pci@6 |
/SYS/IOU0/PCIE7 |
PCIe 8 |
pci_3 |
CMU0/CMP1 |
/pci@3c0/pci@1/pci@0/pci@4 |
/SYS/IOU0/PCIE8 |
PCIe 9 |
pci_15 |
CMU3/CMP1 |
/pci@6c0/pci@1/pci@0/pci@8 |
/SYS/IOU0/PCIE9 |
PCIe 10 |
pci_5 |
CMU2/CMP0 |
/pci@440/pci@1/pci@0/pci@2 |
/SYS/IOU0/PCIE10 |
PCIe 11 |
pci_4 |
CMU2/CMP0 |
/pci@400/pci@1/pci@0/pci@6 |
/SYS/IOU0/PCIE11 |
PCIe 12 |
pci_14 |
CMU3/CMP0 |
/pci@680/pci@1/pci@0/pci@4 |
/SYS/IOU0/PCIE12 |
PCIe 13 |
pci_6 |
CMU2/CMP1 |
/pci@480/pci@1/pci@0/pci@8 |
/SYS/IOU0/PCIE13 |
PCIe 14 |
pci_12 |
CMU3/CMP0 |
/pci@600/pci@1/pci@0/pci@2 |
/SYS/IOU0/PCIE14 |
PCIe 15 |
pci_13 |
CMU3/CMP0 |
/pci@640/pci@1/pci@0/pci@6 |
/SYS/IOU0/PCIE15 |
PCIe 16 |
pci_7 |
CMU2/CMP1 |
/pci@4c0/pci@1/pci@0/pci@4 |
/SYS/IOU0/PCIE16 |
EMS1 |
pci_0 |
CMU0/CMP0 |
/pci@300/pci@1/pci@0/pci@c |
/SYS/IOU0/EMS1 |
EMS2 |
pci_8 |
CMU1/CMP0 |
/pci@500/pci@1/pci@0/pci@0 |
/SYS/IOU0/EMS2 |
EMS3 |
pci_4 |
CMU2/CMP0 |
/pci@400/pci@1/pci@0/pci@c |
/SYS/IOU0/EMS3 |
EMS4 |
pci_12 |
CMU3/CMP0 |
/pci@600/pci@1/pci@0/pci@0 |
/SYS/IOU0/EMS4 |
|
Related Information